Parameter Symbol Min Typ Max Unit Description
Breakdown Voltage Vz - 20 - V Reverse breakdown voltage
Operating Current Iz 10 - 50 mA Test current for Vz measurement
Power Dissipation Ptot - - 625 mW Maximum power dissipation
Junction Temperature Tj - - 150 掳C Maximum junction temperature
Forward Voltage Vf - 1.0 - V Forward voltage at specified If
Leakage Current Ir - - 1 渭A Reverse leakage current at 25掳C

Instructions:

  1. Handling Precautions: Avoid exceeding the maximum junction temperature of 150掳C to prevent damage.
  2. Power Dissipation Management: Ensure that the power dissipation does not exceed 625mW. Use appropriate heat sinking if necessary.
  3. Voltage Regulation: The device is designed to regulate at a nominal breakdown voltage of 20V. Ensure operating conditions are within the specified range for reliable performance.
  4. Current Limiting: When using the device in circuits, ensure that the operating current stays within the recommended range (10mA to 50mA) to maintain stability and avoid overheating.
  5. Leakage Consideration: Account for the reverse leakage current, especially at higher temperatures, as it can affect circuit performance.