Details
BUY YH5092 https://www.utsource.net/itm/p/12611195.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | YH5092 | |
| Type | Hall Effect Sensor | |
| Operating Voltage (Vcc) | Supply Voltage Range | 4.5V to 24V |
| Output Type | Open Collector | |
| Output Current | Maximum Output Current | 20mA |
| Sensitivity | Magnetic Field Sensitivity | -100 Gauss to -300 Gauss |
| Response Time | Typical Response Time | 100 渭s |
| Operating Temperature | Temperature Range for Operation | -40掳C to 85掳C |
| Storage Temperature | Temperature Range for Storage | -40掳C to 125掳C |
| Package Type | TO-92 | |
| Polarity | Bipolar | |
| Quiescent Current | Typical Quiescent Current | 10 渭A |
| Output State | Active Low |
Instructions for Use
Power Supply:
- Connect the Vcc pin to a power supply within the range of 4.5V to 24V.
- Connect the GND pin to the ground of the power supply.
Output Connection:
- The output is an open collector, so connect a pull-up resistor between the output pin and Vcc.
- The typical value for the pull-up resistor is 1k惟 to 10k惟.
Magnetic Field Sensing:
- Place the sensor in the magnetic field you wish to detect.
- The sensor will switch its output to low when the magnetic field strength exceeds the sensitivity threshold (-100 Gauss to -300 Gauss).
Response Time:
- The sensor has a typical response time of 100 渭s, which means it can detect changes in the magnetic field quickly.
Temperature Considerations:
- Ensure the operating temperature is within the range of -40掳C to 85掳C for reliable operation.
- Store the sensor in a temperature range of -40掳C to 125掳C.
Handling:
- Handle the sensor with care to avoid damage.
- Avoid exposing the sensor to excessive mechanical stress or humidity.
Testing:
- To test the sensor, apply a known magnetic field and check the output state using a multimeter or an oscilloscope.
By following these instructions, you can ensure optimal performance and longevity of the YH5092 Hall Effect Sensor.
(For reference only)View more about YH5092 on main site