MMA2202KEGR2

MMA2202KEGR2


Specifications
Details

BUY MMA2202KEGR2 https://www.utsource.net/itm/p/12611219.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VDD Operating 1.8 3.6 V
Output Type Open-Drain
Acceleration Range X, Y Axis 卤2 卤8 g
Bandwidth Low Power Mode 50 Hz
Current Consumption IDD Sleep Mode 0.5 渭A
Current Consumption IDD Active Mode 170 渭A
Shock Survival 10000 g
Operating Temperature TOPR -40 85 掳C

Instructions for MMA2202KEGR2

  1. Power Supply:

    • Connect the supply voltage (VDD) to a stable power source within the range of 1.8V to 3.6V.
  2. Output Configuration:

    • The device has an open-drain output type. Ensure proper pull-up resistors are used on the output lines if interfacing with logic levels higher than the supply voltage.
  3. Acceleration Range Selection:

    • Configure the acceleration range for the X and Y axes as needed using the configuration registers. The ranges can be set to 卤2g or 卤8g depending on the application requirements.
  4. Bandwidth Setting:

    • Set the bandwidth in low-power mode to 50Hz for optimal performance in applications requiring lower power consumption.
  5. Power Modes:

    • Utilize sleep mode to minimize current consumption when not actively measuring acceleration. In sleep mode, the device consumes approximately 0.5渭A.
    • Switch to active mode for continuous measurement, where the device consumes around 170渭A.
  6. Shock Resistance:

    • The device is designed to withstand shocks up to 10,000g, ensuring robust operation in harsh environments.
  7. Temperature Considerations:

    • Operate the device within the temperature range of -40掳C to +85掳C to ensure reliable performance.
  8. Handling Precautions:

    • Follow standard electrostatic discharge (ESD) precautions when handling the device to prevent damage.
(For reference only)

View more about MMA2202KEGR2 on main site