Details
BUY UPC1905 https://www.utsource.net/itm/p/12611279.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | - | 2.7 | - | 5.5 | V |
| Output Voltage | VOUT | - | - | 3.3 | - | V |
| Output Current | IOUT | - | - | 1.5 | - | A |
| Quiescent Current | IQ | No Load | - | 10 | - | 渭A |
| Dropout Voltage | VDROPOUT | IOUT = 1.5A | - | 0.3 | - | V |
| Thermal Shutdown | TSD | - | - | 160 | - | 掳C |
| Operating Temperature | TOPR | - | -40 | - | 85 | 掳C |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the power supply within the specified range (2.7V to 5.5V).
Output Connection:
- Ensure the load is connected to the output (VOUT) which provides a regulated 3.3V.
Ground Connection:
- Connect the ground (GND) of the power supply and the load to the GND pin of the UPC1905.
Thermal Management:
- Ensure adequate heat dissipation to prevent the device from exceeding the thermal shutdown temperature (160掳C). Consider using a heatsink if necessary.
Quiescent Current:
- The quiescent current is typically 10 渭A when no load is connected. This should be considered in low-power applications.
Dropout Voltage:
- The dropout voltage is 0.3V at maximum output current (1.5A). Ensure the input voltage is at least 0.3V higher than the output voltage to maintain regulation.
Operating Temperature:
- The device operates within a temperature range of -40掳C to 85掳C. Avoid operating outside this range to ensure reliable performance.
Storage and Handling:
- Store the device in a dry environment and handle with care to avoid damage from electrostatic discharge (ESD).
Testing:
- Before integrating into a circuit, test the device under typical operating conditions to verify proper functionality.
View more about UPC1905 on main site