TLP280

TLP280


Specifications
SKU
12611329
Details

BUY TLP280 https://www.utsource.net/itm/p/12611329.html

Below is the parameter table and instructions for the TLP280 optocoupler:

TLP280 Parameter Table

Parameter Symbol Min Typical Max Unit
Forward Current (IF) IF - 15 60 mA
Forward Voltage (VF) VF 1.1 1.3 1.6 V
Reverse Voltage (VR) VR - - 5 V
Collector-Emitter Breakdown Voltage (VCEO) VCEO - - 70 V
Collector Current (IC) IC - 15 50 mA
Current Transfer Ratio (CTR) CTR 50 100 200 %
Rise Time (tR) tR - 1.5 4.0 渭s
Fall Time (tF) tF - 1.5 4.0 渭s
Storage Temperature Range Tstg -40 - 110 掳C
Operating Temperature Range Topr -40 - 105 掳C

TLP280 Instructions

  1. Handling Precautions:

    • ESD Protection: Handle the TLP280 with care to avoid electrostatic discharge (ESD). Use grounded wrist straps and anti-static mats.
    • Temperature Sensitivity: Ensure that the operating temperature does not exceed the specified range to prevent damage.
  2. Mounting:

    • Soldering Temperature: Solder the TLP280 at a maximum temperature of 260掳C for up to 10 seconds. Avoid prolonged exposure to high temperatures.
    • Mechanical Stress: Do not apply excessive mechanical stress to the leads or body of the device during mounting.
  3. Electrical Connections:

    • Forward Current (IF): Ensure that the forward current through the LED does not exceed 60 mA to prevent damage.
    • Collector-Emitter Voltage (VCEO): The voltage across the collector and emitter should not exceed 70 V.
    • Reverse Voltage (VR): The reverse voltage across the LED should not exceed 5 V.
  4. Current Transfer Ratio (CTR):

    • Operating Range: The CTR ranges from 50% to 200%. This parameter is crucial for ensuring reliable signal transfer between the input and output circuits.
  5. Timing Parameters:

    • Rise Time (tR) and Fall Time (tF): Both rise time and fall time are typically around 1.5 渭s, with a maximum of 4.0 渭s. These parameters are important for applications requiring fast switching.
  6. Storage and Operating Temperature:

    • Storage Temperature: Store the TLP280 in a dry environment within the temperature range of -40掳C to 110掳C.
    • Operating Temperature: Operate the TLP280 within the temperature range of -40掳C to 105掳C to ensure optimal performance.
  7. Testing:

    • Initial Testing: Before integrating the TLP280 into your circuit, perform initial testing to verify its functionality and parameters.
    • Regular Inspection: Regularly inspect the device for any signs of wear or damage, especially if it is used in harsh environments.

By following these instructions and adhering to the specified parameters, you can ensure the reliable and efficient operation of the TLP280 optocoupler in your applications.