ML4824IP1

ML4824IP1


Specifications
SKU
12611336
Details

BUY ML4824IP1 https://www.utsource.net/itm/p/12611336.html

Parameter Symbol Min Typical Max Unit
Supply Voltage Vcc 4.5 - 5.5 V
Operating Temperature Topr -40 - 85 °C
Storage Temperature Tstg -65 - 150 °C
Output Current (Max) Iout - 50 100 mA
Quiescent Current Iq - 10 20 μA
Shutdown Current Isd - 0.1 1 μA
Output Voltage (Min) Voutmin 1.2 - - V
Output Voltage (Max) Voutmax - - 5.5 V
Dropout Voltage Vdo - 200 300 mV
Load Regulation ΔVout/ΔIout - 0.5 1 mV/mA
Line Regulation ΔVout/ΔVin - 0.5 1 mV/V
PSRR (1 kHz) PSRR - 70 - dB
Thermal Resistance (θJA) θJA - 150 - °C/W

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 4.5V to 5.5V.
    • Use appropriate decoupling capacitors (typically 100nF and 10μF) close to the Vcc pin to stabilize the supply.
  2. Output Configuration:

    • The output voltage can be adjusted using external resistors if the device supports it.
    • Ensure the load current does not exceed the maximum output current of 100mA.
  3. Thermal Management:

    • The thermal resistance (θJA) is 150°C/W. Ensure adequate heat dissipation, especially when operating at high currents or in high ambient temperatures.
  4. Shutdown Mode:

    • To put the device into shutdown mode, pull the shutdown pin low. The shutdown current is typically 0.1μA.
    • To resume operation, bring the shutdown pin high.
  5. Operating Temperature:

    • The device is designed to operate between -40°C and 85°C. Ensure the operating environment stays within these limits to avoid damage.
  6. Storage Temperature:

    • Store the device in an environment where the temperature ranges from -65°C to 150°C.
  7. Electrostatic Discharge (ESD) Protection:

    • Handle the device with care to prevent ESD damage. Use proper ESD protection measures during handling and installation.
  8. Mounting:

    • Follow the recommended PCB layout and mounting guidelines provided by the manufacturer to ensure optimal performance and reliability.
  9. Testing:

    • Before finalizing the design, test the device under various conditions to ensure it meets the required specifications.
  10. Compliance:

    • Ensure the device complies with all relevant safety and regulatory standards for your application.
(For reference only)

View more about ML4824IP1 on main site