Details
BUY 20LC20U https://www.utsource.net/itm/p/12611388.html
| Parameter | Symbol | Min | Typical | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Operating Voltage | VCC | 2.7 | - | 5.5 | V | Supply voltage range |
| Standby Current | ICC(S) | - | 0.1 | - | 渭A | Current consumption in standby mode |
| Active Current | ICC(A) | - | 3.0 | - | mA | Current consumption in active mode |
| Data Retention Time | TDR | - | 10 | - | Years | Data retention time at 85掳C |
| Write Cycle Time | TWC | - | 5 | - | ms | Time required to complete a write cycle |
| Page Write Time | TPW | - | 1.5 | - | ms | Time required to write one page (16 bytes) |
| Read Access Time | TRA | - | 100 | - | ns | Time required to access data during read operations |
| Operating Temperature | Toper | -40 | - | 85 | 掳C | Operating temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | Storage temperature range |
Instructions for 20LC20U
Power Supply:
- Ensure the supply voltage (VCC) is within the specified range of 2.7V to 5.5V.
- Connect the ground (GND) pin to a stable ground reference.
Data Retention:
- The device retains data for up to 10 years at 85掳C. Store the device in a cool, dry environment to maximize data retention.
Write Operations:
- A write cycle takes approximately 5 milliseconds.
- Writing a single page (16 bytes) takes about 1.5 milliseconds.
- Ensure that the device is not powered down or disturbed during a write cycle to avoid data corruption.
Read Operations:
- The read access time is approximately 100 nanoseconds.
- Ensure that the device is properly configured and the address lines are set correctly before initiating a read operation.
Operating and Storage Temperatures:
- The device operates reliably between -40掳C and 85掳C.
- Store the device between -65掳C and 150掳C to ensure long-term reliability.
Standby Mode:
- The device consumes approximately 0.1 渭A in standby mode.
- Use the standby mode to conserve power when the device is not in use.
Active Mode:
- The device consumes approximately 3.0 mA in active mode.
- Ensure that the power supply can handle the current requirements during active operations.
Handling Precautions:
- Handle the device with care to avoid static discharge, which can damage the internal circuitry.
- Follow proper soldering techniques and avoid excessive heat during installation.
Programming:
- Refer to the device datasheet for specific programming sequences and command sets.
- Use appropriate software tools or microcontrollers to interface with the device.
Pin Configuration:
- Ensure that all pins are connected as specified in the datasheet to avoid damage or malfunction.
- Double-check connections before applying power to the device.
View more about 20LC20U on main site