Details
BUY TOSHIBA TLP250H(F) https://www.utsource.net/itm/p/12611433.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Forward Voltage | VF | IF = 10 mA | 1.1 | 1.3 | 1.5 | V |
| Reverse Breakdown Voltage | VBR | IR = 1 mA | 5 | - | 7 | V |
| Forward Current | IF | VR = 0 V | - | 15 | - | mA |
| Reverse Current | IR | VR = VBR | - | 1 | - | mA |
| Output Collector-Emitter | VCEO(s) | IC = 500 mA, TOPR = 25°C | - | 30 | - | V |
| Output Collector Current | ICM | VCES = 5 V, tW = 1 ms | - | 1.5 | - | A |
| Propagation Delay Time | tpLH | VINL → VIH, VOH = 1.4 V | - | 1 | 2 | μs |
| Propagation Delay Time | tpHL | VINH → VIL, VOL = 0.4 V | - | 1 | 2 | μs |
| Power Dissipation | PD | Ta = 25°C | - | 625 | - | mW |
| Operating Temperature | TOPR | -40 | - | 105 | °C |
Instructions for TOSHIBA TLP250H(F):
Mounting and Handling:
- Ensure proper handling to avoid damage due to electrostatic discharge (ESD).
- Use appropriate tools and follow anti-static procedures.
Power Supply Connection:
- Connect the power supply ensuring correct polarity.
- Ensure the power supply voltage is within the specified limits to prevent damage.
Input Signal:
- Apply input signals within the rated forward current (IF) and ensure reverse voltage does not exceed the breakdown voltage (VBR).
Output Load:
- Connect the load to the output terminals ensuring the collector-emitter voltage (VCEO) and collector current (ICM) are within the specified limits.
Heat Management:
- Consider heat dissipation requirements, especially when operating near maximum power dissipation (PD). Use heatsinks if necessary.
Operating Temperature:
- Operate the device within the specified temperature range (-40°C to +105°C) to ensure reliable performance.
Propagation Delay:
- Account for propagation delay times in system timing design to ensure accurate operation.
Storage:
- Store in a dry, cool place away from direct sunlight and sources of heat.
View more about TOSHIBA TLP250H(F) on main site