| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 2.7 | - | 5.5 | V | Operating input voltage range |
| Output Voltage | VOUT | - | 3.3 | - | V | Fixed output voltage |
| Output Current | IOUT | - | 1.2 | - | A | Maximum continuous output current |
| Quiescent Current | IQ | - | 60 | - | μA | Quiescent current at no load |
| Dropout Voltage | VDROPOUT | - | 300 | - | mV | Typical dropout voltage at full load |
| Load Regulation | ΔVOUT/ΔIOUT | - | 0.5 | - | % | Change in output voltage with load current |
| Line Regulation | ΔVOUT/ΔVIN | - | 0.05 | - | % | Change in output voltage with input voltage |
| Efficiency | η | - | 90 | - | % | Typical efficiency at full load |
| Operating Temperature | Toper | -40 | - | 85 | °C | Operating temperature range |
| Storage Temperature | Tstg | -65 | - | 150 | °C | Storage temperature range |
| Thermal Resistance (θJA) | - | - | 120 | - | °C/W | Junction-to-ambient thermal resistance |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the positive terminal of the power supply.
- Ensure the input voltage is within the specified range (2.7V to 5.5V).
Output Connection:
- Connect the output voltage (VOUT) to the load.
- The fixed output voltage is 3.3V.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the circuit.
Capacitors:
- Place a 1μF ceramic capacitor close to the input pin (VIN) to filter out noise and stabilize the input voltage.
- Place a 1μF ceramic capacitor close to the output pin (VOUT) to filter out noise and stabilize the output voltage.
Thermal Management:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- Consider using a heatsink if the junction-to-ambient thermal resistance (θJA) needs to be reduced.
Load Regulation:
- The load regulation is typically 0.5%, meaning the output voltage will change by 0.5% for a full load change.
Line Regulation:
- The line regulation is typically 0.05%, meaning the output voltage will change by 0.05% for a change in input voltage.
Efficiency:
- The typical efficiency is 90% at full load, but this can vary depending on the specific application conditions.
Operating and Storage Temperature:
- Ensure the device operates within the specified temperature range (-40°C to 85°C).
- Store the device within the storage temperature range (-65°C to 150°C).
Handling Precautions:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Follow proper soldering techniques to avoid thermal stress during assembly.