Details
BUY DS2E-M-DC12V https://www.utsource.net/itm/p/12611492.html
| Parameter | Description | Value |
|---|---|---|
| Model | Model Number | DS2E-M-DC12V |
| Type | Device Type | Electromagnetic Relay |
| Voltage | Operating Voltage | 12V DC |
| Current | Coil Current | 40mA |
| Power | Coil Power | 0.48W |
| Contact Form | Contact Configuration | SPDT (Single Pole Double Throw) |
| Contact Rating | Contact Current | 10A at 250V AC |
| Insulation Resistance | Insulation Between Contacts | >100M惟 at 500V DC |
| Dielectric Strength | Dielectric Strength Between Contacts | 1000V AC for 1 minute |
| Operating Temperature | Operating Temperature Range | -40掳C to +85掳C |
| Storage Temperature | Storage Temperature Range | -40掳C to +125掳C |
| Humidity | Relative Humidity | 5% to 95% RH (Non-condensing) |
| Life Expectancy | Mechanical Life | 10 million operations |
| Electrical Life | Electrical Life (at rated load) | 100,000 operations |
| Dimensions | Dimensions (L x W x H) | 35mm x 20mm x 25mm |
| Weight | Weight | 30g |
Instructions
Installation:
- Ensure the relay is installed in a well-ventilated area to prevent overheating.
- Secure the relay using the provided mounting hardware to avoid mechanical stress on the terminals.
Wiring:
- Connect the control circuit to the coil terminals (1 and 2).
- Connect the load circuit to the contact terminals (3, 4, and 5) as per the contact form (SPDT).
Operation:
- Apply the operating voltage (12V DC) to the coil terminals to energize the relay.
- When the relay is energized, the normally open (NO) contact will close, and the normally closed (NC) contact will open.
- When the relay is de-energized, the contacts will return to their default positions.
Maintenance:
- Regularly inspect the relay for any signs of wear or damage.
- Clean the relay with a soft, dry cloth to remove dust and debris.
Safety:
- Do not exceed the rated voltage or current to avoid damage to the relay.
- Ensure the relay is disconnected from the power source before performing any maintenance or testing.
- Use appropriate personal protective equipment (PPE) when handling electrical components.
View more about DS2E-M-DC12V on main site