BUY MBRF20U100CTA https://www.utsource.net/itm/p/12611505.html
| Parameter | Symbol | Value | Unit |
|---|---|---|---|
| Maximum Repetitive Peak Reverse Voltage | VRRM | 100 | V |
| Maximum RMS Voltage (Sinusoidal) | VRMS | 70.7 | V |
| Maximum DC Blocking Voltage | VDC | 100 | V |
| Maximum Average Rectified Output Current (Tc = 100掳C) | IO(AV) | 20 | A |
| Maximum Average Rectified Output Current (Tc = 75掳C) | IO(AV) | 25 | A |
| Maximum Non-Repetitive Peak Surge Current (Half Sine-Wave, 8.3 ms) | IFSM | 400 | A |
| Junction Temperature Range | TJ | -55 to +150 | 掳C |
| Storage Temperature Range | TSTG | -55 to +150 | 掳C |
| Operating Temperature Range | TOPR | -55 to +125 | 掳C |
| Forward Voltage Drop at Rated Current (IO = 20 A) | VF | 1.0 | V |
| Reverse Leakage Current at Maximum Reverse Voltage (VRRM = 100 V, TJ = 25掳C) | IR | 100 | 渭A |
| Reverse Recovery Time (IF = 20 A, di/dt = 200 A/渭s) | trr | 120 | ns |
Instructions for Use:
Mounting:
- Ensure proper heat dissipation by mounting the diode on a heatsink if operating at high currents.
- Avoid mechanical stress on the leads during soldering and handling.
Soldering:
- Use a temperature-controlled soldering iron.
- Do not exceed a soldering temperature of 260掳C for more than 10 seconds.
- Allow the diode to cool naturally after soldering.
Electrical Connections:
- Connect the anode to the positive side of the circuit and the cathode to the negative side.
- Ensure that the reverse voltage does not exceed the maximum rated value of 100V.
Thermal Management:
- Monitor the junction temperature to ensure it remains within the specified range (-55掳C to +150掳C).
- Use thermal paste or a thermal pad between the diode and the heatsink for better thermal conductivity.
Surge Current Handling:
- The diode can handle surge currents up to 400A for short durations (half sine-wave, 8.3 ms). Ensure that these conditions are not exceeded to avoid damage.
Storage:
- Store the diode in a dry, cool place away from direct sunlight.
- Handle with care to prevent static discharge, which can damage the diode.
Testing:
- Before installing the diode in a circuit, test its forward and reverse characteristics using a multimeter or a dedicated diode tester.
- Verify that the forward voltage drop is within the specified range (1.0V at 20A).
Compliance:
- Ensure that the diode complies with all relevant safety and regulatory standards for your application.
View more about MBRF20U100CTA on main site