| Parameter | Symbol | Test Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | 4.5 | 18 | V | ||
| Output Current | IOUT | VIN = 12V | 30 | A | ||
| Continuous Current Limit | ICONT | VIN = 12V, Ta = 25掳C | 30 | A | ||
| Peak Current Limit | IPEAK | VIN = 12V, Ta = 25掳C | 45 | A | ||
| Power Dissipation | PD | VIN = 12V, R胃JA = 62掳C/W | 22.4 | W | ||
| Junction Temperature | TJ | -40 | 150 | 掳C | ||
| Storage Temperature | TSTG | -65 | 150 | 掳C |
Instructions for IRPS5401MTRPBF:
- Power Supply Considerations: Ensure the input voltage (VIN) is within the specified range of 4.5V to 18V. Exceeding these limits can damage the device.
- Heat Management: Given the power dissipation capability and thermal resistance, ensure adequate heat sinking or cooling mechanisms are in place, especially when operating near the maximum continuous current limit.
- Current Limitation: The device has a continuous current limit of 30A and a peak current limit of 45A. Design your circuit to stay within these limits to avoid overheating or potential damage.
- Operating Temperature: Keep the junction temperature (TJ) within the -40掳C to 150掳C range. Monitor the temperature during operation to prevent overheating.
- Storage Conditions: Store the device in an environment where the temperature does not drop below -65掳C or rise above 150掳C.
- Installation: Ensure proper installation following manufacturer guidelines to maintain optimal performance and reliability.