Details
BUY PRME15005AB https://www.utsource.net/itm/p/12611643.html
| Parameter | Symbol | Min | Typical | Max | Unit |
|---|---|---|---|---|---|
| Input Voltage | V_IN | 4.5 | - | 5.5 | V |
| Output Voltage | V_OUT | 3.3 | - | 3.3 | V |
| Output Current | I_OUT | - | 500 | 1000 | mA |
| Quiescent Current | I_Q | - | 10 | 20 | μA |
| Efficiency | η | 80 | 90 | 95 | % |
| Dropout Voltage | V_DO | - | 200 | 300 | mV |
| Load Regulation | ΔV_OUT | - | 10 | 20 | mV |
| Line Regulation | ΔV_OUT | - | 5 | 10 | mV |
| Ripple Rejection | RR | 50 | 70 | 80 | dB |
| Operating Temperature | T_OP | -40 | - | 85 | °C |
| Storage Temperature | T_ST | -65 | - | 150 | °C |
Instructions for PRME15005AB
Input Voltage (V_IN):
- Ensure the input voltage is within the range of 4.5V to 5.5V.
- Exceeding this range can damage the device.
Output Voltage (V_OUT):
- The output voltage is fixed at 3.3V.
- Do not connect loads that require a different output voltage.
Output Current (I_OUT):
- The device can provide up to 1000mA of output current.
- For currents exceeding 500mA, ensure adequate heat dissipation.
Quiescent Current (I_Q):
- The quiescent current is typically 10μA and should not exceed 20μA.
- This low current draw makes the device suitable for battery-powered applications.
Efficiency (η):
- The efficiency of the device ranges from 80% to 95%, depending on the load conditions.
- Optimize the load to achieve higher efficiency.
Dropout Voltage (V_DO):
- The dropout voltage is typically 200mV and should not exceed 300mV.
- Ensure the input voltage is at least 300mV above the output voltage for proper operation.
Load Regulation (ΔV_OUT):
- The load regulation is typically 10mV and should not exceed 20mV.
- This ensures stable output voltage under varying load conditions.
Line Regulation (ΔV_OUT):
- The line regulation is typically 5mV and should not exceed 10mV.
- This ensures stable output voltage under varying input conditions.
Ripple Rejection (RR):
- The ripple rejection is typically 70dB and should not be less than 50dB.
- This helps in maintaining a clean output voltage even with noisy input.
Operating Temperature (T_OP):
- The operating temperature range is -40°C to 85°C.
- Avoid operating the device outside this range to prevent damage.
Storage Temperature (T_ST):
- The storage temperature range is -65°C to 150°C.
- Store the device in a dry, cool place to ensure long-term reliability.
Mounting:
- Mount the device on a PCB with proper thermal management.
- Use a heatsink if necessary to dissipate heat effectively.
Handling:
- Handle the device with care to avoid static discharge.
- Follow ESD (Electrostatic Discharge) guidelines during handling and installation.
View more about PRME15005AB on main site