Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating range 3.0 - 5.5 V
Standby Current Isb Vcc = 5V, EN = L - 1 - μA
Active Current Icc Vcc = 5V, TxD = 20 kbps - 9 - mA
Receiver Input Voltage V(Iin) VIH = 0.7 × Vcc 2.1 - 3.85 V
Output Low Voltage VOL IOH = 4mA 0.1 - 0.4 V
Output High Voltage VOH IOL = -4mA 4.2 - Vcc-0.4 V
Differential Input Level Vdiff Receiver threshold 200 - - mV
Data Rate Bit/s Maximum - - 1 Mbps
Operating Temperature Toper - -40 - 125 °C

Instructions for TJA1020T/CM118

  1. Power Supply Connection:

    • Connect the Vcc pin to a stable power supply within the operating range of 3.0V to 5.5V.
    • Ensure the GND pin is connected to the system ground.
  2. Enable Pin (EN):

    • The EN pin controls the active or standby state of the device.
    • Set EN high (Vcc) to enable the transceiver.
    • Set EN low (GND) to put the device into low-power standby mode.
  3. Data Transmission:

    • Use the TXD and RXD pins for data transmission and reception.
    • Ensure the baud rate does not exceed 1 Mbps for reliable communication.
  4. Termination Resistors:

    • For optimal performance, connect a 120Ω termination resistor between CAN_H and CAN_L at both ends of the bus.
  5. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 125°C to ensure reliability and longevity.
  6. Electrostatic Discharge (ESD) Protection:

    • Handle the device with appropriate ESD precautions to prevent damage.
  7. Mounting and Layout:

    • Follow recommended PCB layout guidelines to minimize noise and interference.
  8. Signal Integrity:

    • Keep signal traces as short as possible to maintain signal integrity, especially for high-speed applications.
(For reference only)