Parameter Symbol Min Typ Max Unit Description
Forward Current IF - 16 20 mA Maximum forward current through the LED
Forward Voltage VF 1.1 1.3 1.5 V Forward voltage at IF = 20mA
Reverse Voltage VR - - 5 V Maximum reverse voltage across the LED
Output Supply Voltage VCC 4.5 - 20 V Operating supply voltage range
Output Leakage Current IOL - 1 10 渭A Output leakage current at VCC = 20V, T_A = 85掳C
Propagation Delay Time tpd 5 9 15 ns Propagation delay time
Pulse Width Distortion tpw - 1 3 ns Pulse width distortion
Rise Time tr 5 7 10 ns Rise time
Fall Time tf 5 7 10 ns Fall time
Common Mode Transient Immunity CMTI 25 - - kV/渭s Common mode transient immunity
Operating Temperature T_op -40 - 85 掳C Operating temperature range
Storage Temperature T_stg -55 - 125 掳C Storage temperature range

Instructions for HCPL-6N139:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 4.5V to 20V.
  2. LED Drive:

    • The LED should be driven with a current between 16mA and 20mA for optimal performance. Avoid exceeding these limits to prevent damage.
  3. Output Handling:

    • Be aware of the output leakage current which can reach up to 10渭A under extreme conditions (VCC = 20V, T_A = 85掳C).
  4. Timing Considerations:

    • Take into account the propagation delay time (tpd), rise time (tr), and fall time (tf) when designing circuits that depend on precise timing.
  5. Environmental Conditions:

    • Operate the device within the temperature range of -40掳C to 85掳C for reliable performance. Store it in environments ranging from -55掳C to 125掳C.
  6. Electrostatic Discharge (ESD) Sensitivity:

    • Handle the device with care as it may be sensitive to ESD; use appropriate precautions during handling and installation.
  7. Common Mode Transient Immunity (CMTI):

    • For applications where high-speed switching or noise is present, consider the CMTI rating to ensure robust operation.
  8. Mounting and Connections:

    • Ensure proper mounting and connection practices to maintain electrical integrity and thermal management.