Details
BUY DS1010-250 https://www.utsource.net/itm/p/12611867.html
| Parameter | Description | Value |
|---|---|---|
| Part Number | Part number | DS1010-250 |
| Type | Type of device | Digital Potentiometer |
| Resistance Range | Range of resistance values | 0 to 10k惟 |
| Resolution | Minimum step change in resistance | 10惟 |
| Tolerance | Accuracy of resistance value | 卤20% |
| Operating Voltage | Supply voltage range | 2.7V to 5.5V |
| Operating Current | Maximum current through the wiper | 1mA |
| Wiper Resistance | Maximum resistance between wiper and terminal | 100惟 |
| Power Rating | Maximum power dissipation | 25mW |
| Temperature Range | Operating temperature range | -40掳C to +85掳C |
| Package | Physical package type | SOIC-8 |
| Interface | Communication interface | SPI |
| Number of Channels | Number of independent potentiometers | 1 |
| Endurance | Number of expected cycles before failure | 1,000,000 |
Instructions for Use
Power Supply:
- Connect the VCC pin to a supply voltage between 2.7V and 5.5V.
- Connect the GND pin to the ground.
Communication Interface:
- Use the SPI interface to communicate with the DS1010-250.
- Connect the SCLK (Serial Clock) pin to the clock signal from your microcontroller.
- Connect the MOSI (Master Out Slave In) pin to the data output from your microcontroller.
- Connect the CS (Chip Select) pin to the chip select signal from your microcontroller.
Initialization:
- Ensure the CS pin is high to deselect the device during initialization.
- To select the device, pull the CS pin low.
- Send the appropriate command sequence to initialize the device and set the wiper position.
Setting Wiper Position:
- Use the
Wiper Writecommand to set the wiper position. - The wiper position is determined by a 7-bit value (0 to 127), where each step changes the resistance by 10惟.
- Example command sequence:
- CS low
- Send
Wiper Writecommand (0x00) - Send 7-bit wiper position value
- CS high
- Use the
Reading Wiper Position:
- Use the
Wiper Readcommand to read the current wiper position. - Example command sequence:
- CS low
- Send
Wiper Readcommand (0x0F) - Read 7-bit wiper position value
- CS high
- Use the
Powering Down:
- To power down the device, set the wiper position to the desired value and then disconnect the VCC supply.
- Alternatively, use the
Shutdowncommand to place the device in a low-power mode.
Handling:
- Handle the device with care to avoid static discharge.
- Store in a dry, cool place when not in use.
Troubleshooting:
- If the device does not respond, check the connections and ensure the correct supply voltage.
- Verify the communication protocol and command sequences.
For detailed command codes and timing diagrams, refer to the datasheet provided by the manufacturer.
(For reference only)View more about DS1010-250 on main site