74S03

74S03


Specifications
SKU
12611869
Details

BUY 74S03 https://www.utsource.net/itm/p/12611869.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.75 5.0 5.25 V
Input Low Voltage VIL Input Low 0.0 - 0.8 V
Input High Voltage VIH Input High 2.0 - VCC V
Output Low Voltage VOL IOL = 16 mA 0.0 - 0.5 V
Output High Voltage VOH IOH = -0.4 mA 2.7 - VCC V
Propagation Delay Time tpd Typical at VCC = 5V, TA = 25掳C - 9 - ns
Power Dissipation PD Maximum at TA = 25掳C - - 500 mW
Operating Temperature Range TA Commercial Grade 0 - 70 掳C
Storage Temperature Range TSTG - -65 - 150 掳C

Instructions for Using 74S03:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 4.75V to 5.25V.
    • Connect the ground (GND) pin to a stable 0V reference.
  2. Input Signals:

    • Apply input signals (VIL and VIH) that meet the specified voltage levels.
    • Avoid applying voltages outside the VCC range to prevent damage.
  3. Output Signals:

    • The output low voltage (VOL) should not exceed 0.5V when sourcing 16mA.
    • The output high voltage (VOH) should be at least 2.7V when sinking -0.4mA.
  4. Propagation Delay:

    • The typical propagation delay time (tpd) is 9ns at VCC = 5V and TA = 25掳C.
    • Consider this delay when designing timing-sensitive circuits.
  5. Power Dissipation:

    • Ensure the power dissipation (PD) does not exceed 500mW to avoid overheating.
    • Use appropriate heat sinks or cooling methods if necessary.
  6. Temperature Range:

    • Operate the device within the commercial temperature range of 0掳C to 70掳C.
    • Store the device within the storage temperature range of -65掳C to 150掳C.
  7. Handling:

    • Handle the 74S03 with care to avoid static discharge, which can damage the device.
    • Follow proper ESD (Electrostatic Discharge) precautions during handling and installation.
(For reference only)

View more about 74S03 on main site