| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VCC | Operating | 4.5 | - | 40 | V |
| Quiescent Current | IQ | No Load, VCC = 24V | - | 100 | - | 渭A |
| Output Current | IO | Continuous, VCC = 24V | - | 100 | 150 | mA |
| Output Voltage | VOUT | No Load, VCC = 24V | - | 24 | - | V |
| Dropout Voltage | VDROP | IO = 100mA | - | 0.8 | - | V |
| Thermal Shutdown Temperature | TSD | - | - | 160 | - | 掳C |
| Storage Temperature | TSTG | - | -65 | - | 150 | 掳C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the operating range of 4.5V to 40V.
- Connect a bypass capacitor (typically 10渭F) between VCC and GND close to the device to filter out noise and stabilize the supply.
Output Configuration:
- The output can source up to 150mA continuously. For higher currents, ensure adequate heat dissipation.
- Place a load resistor or device between the output and ground.
Thermal Considerations:
- The device has thermal shutdown protection that activates at approximately 160掳C. Ensure proper heat sinking if operating near maximum current or in high ambient temperatures.
Stability:
- To maintain stability, use a minimum load of 10mA.
- If the output is not used, connect it to ground through a resistor to prevent floating.
Storage and Handling:
- Store the device in a temperature range of -65掳C to 150掳C.
- Handle with care to avoid damage from electrostatic discharge (ESD).
Application Notes:
- Refer to the datasheet for detailed application circuits and specific recommendations for your design requirements.
For more detailed information, refer to the official datasheet of the MC33174.