Details
BUY HCPL-0630-500 https://www.utsource.net/itm/p/12612060.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Forward Voltage | V_F | IF = 20 mA | 1.2 | 1.6 | V | |
| Reverse Breakdown Voltage | V_BR | IR = 10 渭A | 5 | V | ||
| Peak Reverse Current | I_PR | VR = VBR | 5 | mA | ||
| Output Collector-Emitter Saturation Voltage | V_CE(sat) | IC = 10 mA, IF = 20 mA | 0.3 | 0.5 | V | |
| Output Collector Leakage Current | I_CBO | VCE = 5 V, IF = 0 mA | 10 | nA | ||
| Propagation Delay Time | tPLH | IF = 20 mA, IC = 10 mA | 20 | 50 | ns | |
| Propagation Delay Time | tPHL | IF = 20 mA, IC = 10 mA | 20 | 50 | ns | |
| Pulse Width Distortion | tPWD | IF = 20 mA, IC = 10 mA | -10 | 10 | ns | |
| Common Mode Transient Immunity | CMTI | IF = 20 mA, IC = 10 mA | 25 | kV/渭s |
Instructions for HCPL-0630-500:
Mounting and Handling:
- Handle the device with care to avoid damage to the leads and body.
- Ensure proper mounting on the PCB to prevent mechanical stress.
Power Supply:
- Apply the recommended input forward current (IF) of 20 mA for optimal performance.
- Ensure the reverse voltage does not exceed the specified breakdown voltage (V_BR).
Signal Integrity:
- Keep signal traces as short as possible to minimize noise and interference.
- Use appropriate bypass capacitors near the power supply pins to ensure stable operation.
Operating Temperature Range:
- Operate within the temperature range specified by the manufacturer to ensure reliability and longevity.
Storage:
- Store in a dry, cool environment to prevent moisture damage.
- Follow ESD handling guidelines to protect against electrostatic discharge.
Testing:
- Perform initial testing at room temperature using the specified test conditions.
- Regularly check output parameters like collector-emitter saturation voltage and leakage current to ensure the device is functioning correctly.
Safety:
- Always adhere to safety standards and guidelines when working with electrical components.
- Avoid exceeding maximum ratings for voltage, current, and power dissipation.
View more about HCPL-0630-500 on main site