MPXV5100DP Parameter Table

Parameter Symbol Min Typ Max Unit
Supply Voltage Vcc 4.5 5.0 5.5 V
Output Voltage (Differential) Vout 0.25 2.5 4.75 V
Differential Pressure Range ΔP -50 0 +50 kPa
Linearity Error ±1.0 % FS
Hysteresis ±0.1 % FS
Temperature Coefficient ±0.05 %/°C
Operating Temperature Range Toper -40 25 125 °C
Storage Temperature Range Tstg -40 25 150 °C
Response Time τ 1 ms
Supply Current Icc 1.0 3.5 6.0 mA

Instructions for MPXV5100DP

  1. Power Supply:

    • Connect the supply voltage (Vcc) to the positive terminal and ground (GND) to the negative terminal.
    • Ensure the supply voltage is within the range of 4.5V to 5.5V.
  2. Signal Connections:

    • Connect the output (Vout) to the analog input of your measurement device.
    • The output voltage will vary linearly with the differential pressure applied to the sensor.
  3. Differential Pressure Application:

    • Apply the differential pressure across the two pressure ports (P1 and P2).
    • Positive pressure should be applied to P1 relative to P2 for a positive output voltage.
    • Negative pressure should be applied to P2 relative to P1 for a negative output voltage.
  4. Temperature Considerations:

    • The sensor is designed to operate within the temperature range of -40°C to 125°C.
    • For storage, ensure the temperature does not exceed 150°C.
  5. Calibration:

    • Calibrate the sensor if necessary to account for any non-linearities or offsets.
    • Use known reference pressures to calibrate the output voltage to the actual pressure values.
  6. Handling and Mounting:

    • Handle the sensor with care to avoid mechanical shock or damage.
    • Mount the sensor in a stable and secure position to prevent vibration and movement that could affect readings.
  7. Response Time:

    • The response time of the sensor is approximately 1 ms, which is suitable for most dynamic applications.
  8. Supply Current:

    • The typical supply current is 3.5 mA, but it can range from 1.0 mA to 6.0 mA depending on operating conditions.