| Parameter | Symbol | Min | Typ | Max | Unit | Notes |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | 2.7 | - | 3.6 | V | |
| Standby Current | Icc | - | 1.0 | 2.0 | 渭A | @ Vcc = 3.0V, Ta = 25掳C |
| Active Current | Icc | - | 2.0 | 3.0 | mA | @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz |
| Operating Temperature | Ta | -40 | - | 85 | 掳C | |
| Storage Temperature | Tstg | -65 | - | 150 | 掳C | |
| Data Retention Time | tDR | 10 | - | - | Years | @ Vcc = 3.0V, Ta = 25掳C |
| Write Cycle Time | tWC | 5 | - | 10 | ms | |
| Page Program Time | tPP | 2.5 | - | 5 | ms | |
| Sector Erase Time | tSE | 30 | - | 60 | ms | |
| Chip Erase Time | tCE | 200 | - | 400 | ms | |
| Data Output Delay | tDO | 0 | 10 | 25 | ns | @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz |
| Address Access Time | tAA | 0 | 10 | 25 | ns | @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz |
| Read Cycle Time | tRC | 0 | 10 | 25 | ns | @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz |
Instructions for Use
Power Supply:
- Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
- The device should be powered with a stable voltage to avoid data corruption.
Temperature:
- Operate the device within the temperature range of -40掳C to 85掳C.
- Store the device within the temperature range of -65掳C to 150掳C.
Current Consumption:
- Monitor the standby current (Icc) which should not exceed 2.0 渭A at 3.0V and 25掳C.
- The active current should be between 2.0 mA and 3.0 mA under typical operating conditions.
Data Retention:
- The device retains data for at least 10 years when powered at 3.0V and operated at 25掳C.
Write and Erase Operations:
- The write cycle time (tWC) is between 5 ms and 10 ms.
- The page program time (tPP) is between 2.5 ms and 5 ms.
- The sector erase time (tSE) is between 30 ms and 60 ms.
- The chip erase time (tCE) is between 200 ms and 400 ms.
Timing Parameters:
- Ensure that the data output delay (tDO) is between 0 ns and 25 ns.
- The address access time (tAA) should be between 0 ns and 25 ns.
- The read cycle time (tRC) should be between 0 ns and 25 ns.
Clock Frequency:
- The device is designed to operate with a clock frequency (fCLK) of up to 1 MHz.
Handling:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Follow proper soldering techniques to ensure reliable connections.
Programming:
- Refer to the specific programming algorithms provided by the manufacturer for writing and erasing operations to ensure data integrity.
Storage:
- Store the device in a dry, cool place to prevent moisture damage and prolong its lifespan.