M5M34051FP

M5M34051FP


Specifications
SKU
12612228
Details

BUY M5M34051FP https://www.utsource.net/itm/p/12612228.html

Parameter Symbol Min Typ Max Unit Notes
Supply Voltage Vcc 2.7 - 3.6 V
Standby Current Icc - 1.0 2.0 渭A @ Vcc = 3.0V, Ta = 25掳C
Active Current Icc - 2.0 3.0 mA @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz
Operating Temperature Ta -40 - 85 掳C
Storage Temperature Tstg -65 - 150 掳C
Data Retention Time tDR 10 - - Years @ Vcc = 3.0V, Ta = 25掳C
Write Cycle Time tWC 5 - 10 ms
Page Program Time tPP 2.5 - 5 ms
Sector Erase Time tSE 30 - 60 ms
Chip Erase Time tCE 200 - 400 ms
Data Output Delay tDO 0 10 25 ns @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz
Address Access Time tAA 0 10 25 ns @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz
Read Cycle Time tRC 0 10 25 ns @ Vcc = 3.0V, Ta = 25掳C, fCLK = 1MHz

Instructions for Use

  1. Power Supply:

    • Ensure the supply voltage (Vcc) is within the range of 2.7V to 3.6V.
    • The device should be powered with a stable voltage to avoid data corruption.
  2. Temperature:

    • Operate the device within the temperature range of -40掳C to 85掳C.
    • Store the device within the temperature range of -65掳C to 150掳C.
  3. Current Consumption:

    • Monitor the standby current (Icc) which should not exceed 2.0 渭A at 3.0V and 25掳C.
    • The active current should be between 2.0 mA and 3.0 mA under typical operating conditions.
  4. Data Retention:

    • The device retains data for at least 10 years when powered at 3.0V and operated at 25掳C.
  5. Write and Erase Operations:

    • The write cycle time (tWC) is between 5 ms and 10 ms.
    • The page program time (tPP) is between 2.5 ms and 5 ms.
    • The sector erase time (tSE) is between 30 ms and 60 ms.
    • The chip erase time (tCE) is between 200 ms and 400 ms.
  6. Timing Parameters:

    • Ensure that the data output delay (tDO) is between 0 ns and 25 ns.
    • The address access time (tAA) should be between 0 ns and 25 ns.
    • The read cycle time (tRC) should be between 0 ns and 25 ns.
  7. Clock Frequency:

    • The device is designed to operate with a clock frequency (fCLK) of up to 1 MHz.
  8. Handling:

    • Handle the device with care to avoid static discharge, which can damage the internal circuits.
    • Follow proper soldering techniques to ensure reliable connections.
  9. Programming:

    • Refer to the specific programming algorithms provided by the manufacturer for writing and erasing operations to ensure data integrity.
  10. Storage:

    • Store the device in a dry, cool place to prevent moisture damage and prolong its lifespan.
(For reference only)

View more about M5M34051FP on main site