AMC1305L25DW

AMC1305L25DW

Category: IC Chips

Specifications
SKU
12612276
Details

BUY AMC1305L25DW https://www.utsource.net/itm/p/12612276.html

Parameter Symbol Min Typical Max Unit Description
Supply Voltage VDD 4.75 5.0 5.25 V Power supply voltage
Output Voltage Range VOUT - 0.5 4.5 V Output voltage range
Common-Mode Input Voltage VCM 0 2.5 5 V Common-mode input voltage
Differential Input Voltage VDIFF -0.1 0 0.1 V Differential input voltage
Input Bias Current IB - 1 3 μA Input bias current
Bandwidth BW - 80 - kHz Bandwidth at unity gain
Gain A 196 200 204 dB Gain at DC
CMRR (DC to 50 Hz) CMRR 110 115 120 dB Common-mode rejection ratio
PSRR (DC to 50 Hz) PSRR 100 105 110 dB Power supply rejection ratio
Offset Voltage VOS -1 0 1 mV Input offset voltage
Quiescent Current IQ 2.5 3 3.5 mA Quiescent current
Operating Temperature Toper -40 - 125 °C Operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range

Instructions for Use

  1. Power Supply:

    • Connect the VDD pin to a 5V power supply.
    • Ensure the power supply is stable and within the specified range (4.75V to 5.25V).
  2. Input Configuration:

    • Connect the differential input signals to the IN+ and IN- pins.
    • The common-mode input voltage should be between 0V and 5V.
    • The differential input voltage should not exceed ±0.1V.
  3. Output Configuration:

    • The output voltage range is from 0.5V to 4.5V.
    • Ensure that the load connected to the output does not draw excessive current.
  4. Biasing and Decoupling:

    • Use decoupling capacitors (e.g., 0.1μF and 10μF) close to the VDD and GND pins to filter out noise and ensure stable operation.
    • Consider using a bias resistor network to set the common-mode voltage if needed.
  5. Temperature Considerations:

    • Operate the device within the temperature range of -40°C to 125°C.
    • Store the device in an environment where the temperature does not exceed -65°C to 150°C.
  6. Handling Precautions:

    • Handle the device with care to avoid static discharge.
    • Follow proper ESD (Electrostatic Discharge) precautions during handling and installation.
  7. Testing and Calibration:

    • Perform initial testing and calibration to ensure the device meets the specified performance parameters.
    • Use a precision voltage source and multimeter for accurate measurements.
  8. Application Notes:

    • Refer to the datasheet and application notes for specific use cases and advanced configurations.
    • For high-precision applications, consider additional filtering and shielding to minimize noise.
(For reference only)