Parameter Symbol Conditions Min Typical Max Unit
Supply Voltage VDD Operating Range 2.7 - 5.25 V
Supply Current (Active) IDD VDD = 5V - 2.0 - mA
Supply Current (Power-Down) IDD VDD = 5V - 10 - μA
Input Voltage Range VIN VDD = 5V 0 - VDD V
Output Voltage Range VOUT VDD = 5V 0 - VDD V
Conversion Time tCONV Single Channel - 20 - μs
Power-Down Time tPD - 5 - μs
Output Data Rate fODR - 100 - kSPS
Differential Nonlinearity DNL -1 0 +1 LSB
Integral Nonlinearity INL -1 0 +1 LSB
Offset Error VOS VDD = 5V - 2 - mV
Gain Error GAIN VDD = 5V - 0.1 - % FS
Temperature Range Toper Operating Range -40 - 125 °C

Instructions for Using AD7367BRUZ

  1. Power Supply:

    • Connect the supply voltage (VDD) to a stable power source within the operating range of 2.7V to 5.25V.
    • Ensure the ground (GND) is properly connected.
  2. Input Configuration:

    • Connect the analog input signals to the VIN pins.
    • The input voltage should be within the range of 0V to VDD.
  3. Output Configuration:

    • The output voltage (VOUT) will be proportional to the input voltage.
    • Ensure the output is connected to the appropriate load or next stage in your circuit.
  4. Power-Down Mode:

    • To enter power-down mode, set the appropriate control signal (e.g., PDN pin) to a high state.
    • The device will enter a low-power state with minimal current consumption.
  5. Conversion and Data Rate:

    • The conversion time is approximately 20 μs for a single channel.
    • Set the output data rate (fODR) according to your application requirements, up to 100 kSPS.
  6. Calibration:

    • Perform any necessary calibration to correct for offset and gain errors.
    • Use the provided DNL and INL specifications to ensure accurate conversions.
  7. Temperature Considerations:

    • The device operates over a temperature range of -40°C to 125°C.
    • Monitor the temperature to ensure it remains within the specified limits.
  8. Handling and Storage:

    • Handle the device with care to avoid damage from electrostatic discharge (ESD).
    • Store the device in a dry, cool environment when not in use.