Details
BUY AD7367BRUZ https://www.utsource.net/itm/p/12612281.html
Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | Operating Range | 2.7 | - | 5.25 | V |
Supply Current (Active) | IDD | VDD = 5V | - | 2.0 | - | mA |
Supply Current (Power-Down) | IDD | VDD = 5V | - | 10 | - | μA |
Input Voltage Range | VIN | VDD = 5V | 0 | - | VDD | V |
Output Voltage Range | VOUT | VDD = 5V | 0 | - | VDD | V |
Conversion Time | tCONV | Single Channel | - | 20 | - | μs |
Power-Down Time | tPD | - | 5 | - | μs | |
Output Data Rate | fODR | - | 100 | - | kSPS | |
Differential Nonlinearity | DNL | -1 | 0 | +1 | LSB | |
Integral Nonlinearity | INL | -1 | 0 | +1 | LSB | |
Offset Error | VOS | VDD = 5V | - | 2 | - | mV |
Gain Error | GAIN | VDD = 5V | - | 0.1 | - | % FS |
Temperature Range | Toper | Operating Range | -40 | - | 125 | °C |
Instructions for Using AD7367BRUZ
Power Supply:
- Connect the supply voltage (VDD) to a stable power source within the operating range of 2.7V to 5.25V.
- Ensure the ground (GND) is properly connected.
Input Configuration:
- Connect the analog input signals to the VIN pins.
- The input voltage should be within the range of 0V to VDD.
Output Configuration:
- The output voltage (VOUT) will be proportional to the input voltage.
- Ensure the output is connected to the appropriate load or next stage in your circuit.
Power-Down Mode:
- To enter power-down mode, set the appropriate control signal (e.g., PDN pin) to a high state.
- The device will enter a low-power state with minimal current consumption.
Conversion and Data Rate:
- The conversion time is approximately 20 μs for a single channel.
- Set the output data rate (fODR) according to your application requirements, up to 100 kSPS.
Calibration:
- Perform any necessary calibration to correct for offset and gain errors.
- Use the provided DNL and INL specifications to ensure accurate conversions.
Temperature Considerations:
- The device operates over a temperature range of -40°C to 125°C.
- Monitor the temperature to ensure it remains within the specified limits.
Handling and Storage:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Store the device in a dry, cool environment when not in use.
View more about AD7367BRUZ on main site