Details
BUY MPX5700GP https://www.utsource.net/itm/p/12612286.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | Operating | 4.5 | - | 5.5 | V |
| Quiescent Current | IQ | VDD = 5V | 1.5 | 2.5 | 3.5 | mA |
| Pressure Range | PRANGE | 14.7 | - | 29.0 | psi | |
| Output at Atmospheric Pressure (14.7 psi) | VOUT(14.7 psi) | VDD = 5V | 0.5 | 0.75 | 1.0 | V |
| Output at Maximum Pressure (29.0 psi) | VOUT(29.0 psi) | VDD = 5V | 4.0 | 4.25 | 4.5 | V |
| Temperature Range | TOP | Operating | -40 | - | 125 | 掳C |
| Temperature Coefficient | TCOUT | Full Scale Span | -0.01 | - | 0.01 | %/掳C |
| Non-Linearity | NL | Full Scale Span | -1.0 | - | 1.0 | % FS |
| Hysteresis | HYST | Full Scale Span | -0.2 | - | 0.2 | % FS |
| Pressure Sensitivity | SP | VDD = 5V, 14.7 to 29.0 psi | 3.5 | 4.0 | 4.5 | mV/psi |
Instructions for Using the MPX5700GP:
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 4.5V to 5.5V.
- Connect the VDD pin to the positive terminal of your power source and the GND pin to the negative terminal.
Pressure Application:
- Apply the pressure to be measured to the pressure port of the sensor.
- The sensor is designed to measure pressures ranging from 14.7 psi to 29.0 psi.
Output Signal:
- The output voltage (VOUT) will vary linearly with the applied pressure.
- At atmospheric pressure (14.7 psi), the output voltage should be around 0.75V.
- At maximum pressure (29.0 psi), the output voltage should be around 4.25V.
Temperature Considerations:
- The sensor operates over a temperature range of -40掳C to 125掳C.
- The temperature coefficient of the output is 卤0.01% per degree Celsius, which means the output may vary slightly with temperature changes.
Calibration:
- For precise measurements, calibrate the sensor using known pressure points.
- Use the non-linearity and hysteresis specifications to account for any deviations in the output.
Mounting:
- Mount the sensor in a location where it is not exposed to excessive mechanical stress or vibration.
- Ensure the sensor is properly sealed if used in environments with high humidity or moisture.
Handling:
- Handle the sensor with care to avoid damage to the pressure port or electrical connections.
- Avoid applying excessive force or torque to the sensor during installation.
Storage:
- Store the sensor in a dry, cool place when not in use.
- Protect the sensor from static electricity by using appropriate handling procedures.