JS1F-24V-F

JS1F-24V-F


Specifications
SKU
12612359
Details

BUY JS1F-24V-F https://www.utsource.net/itm/p/12612359.html

Parameter Description Value
Part Number Product code JS1F-24V-F
Type Relay SPDT (Single Pole, Double Throw)
Coil Voltage Nominal coil voltage 24V DC
Coil Power Consumption Power consumption at nominal voltage 0.36W
Coil Resistance Resistance at 25掳C 667惟
Contact Form Configuration of contacts 1C/O + 1C/C
Contact Rating Maximum switching capacity 10A @ 250VAC
Insulation Resistance Minimum insulation resistance between contacts 100M惟 (500VDC)
Dielectric Strength Withstand voltage between contacts 1000VAC for 1 minute
Operating Temperature Range of ambient temperature for operation -40掳C to 85掳C
Storage Temperature Range of ambient temperature for storage -40掳C to 85掳C
Humidity Relative humidity range 5% to 95% RH
Mechanical Life Expected number of operations without load 10 million cycles
Electrical Life Expected number of operations under rated load 100,000 cycles
Terminal Type Connection method for wires Solder lug
Mounting Method of installation PC board mount
Dimensions Size of the relay 17.5mm x 12.5mm x 10mm
Weight Mass of the relay 4g

Instructions:

  1. Installation:

    • Ensure the relay is installed on a suitable PCB or mounting surface.
    • Connect the coil terminals to the 24V DC power supply.
    • Connect the load to the appropriate contact terminals (Common, Normally Open, Normally Closed).
  2. Operation:

    • Apply 24V DC to the coil terminals to energize the relay.
    • When the coil is energized, the common contact will switch from the normally closed (NC) position to the normally open (NO) position.
    • When the coil is de-energized, the common contact will return to the NC position.
  3. Maintenance:

    • Regularly inspect the relay for any signs of wear or damage.
    • Ensure the operating environment is within the specified temperature and humidity ranges.
    • If the relay is used in a high-vibration environment, periodically check the connections for tightness.
  4. Safety:

    • Do not exceed the maximum contact ratings to avoid damage or failure.
    • Ensure proper insulation and isolation when handling high voltages.
    • Follow all local electrical codes and regulations.
(For reference only)

View more about JS1F-24V-F on main site