DS1685EN-5+

DS1685EN-5+

Category: IC Chips

Specifications
SKU
12612470
Details

BUY DS1685EN-5+ https://www.utsource.net/itm/p/12612470.html

Parameter Symbol Min Typical Max Unit Notes
Supply Voltage VCC 4.5 5.0 5.5 V Operating voltage range
Standby Current ISB - 1.0 2.0 μA Typical at 25°C, VCC = 5V
Active Current IOP 10 30 50 mA Maximum active current at 25°C, VCC = 5V
Operating Temperature TOPR -40 85 °C Full operating temperature range
Output Voltage (High) VOH 2.4 4.5 5.0 V Minimum output high level at VCC = 5V, IOL = 4mA
Output Voltage (Low) VOL 0 0.4 0.5 V Maximum output low level at VCC = 5V, IOL = 16mA
Input Voltage (High) VIH 2.0 5.0 V Minimum input high level at VCC = 5V
Input Voltage (Low) VIL 0 0.8 V Maximum input low level at VCC = 5V
Propagation Delay tPD 20 35 70 ns Typical propagation delay at VCC = 5V, 25°C
Power-on Reset Time tPOR 100 200 400 ms Maximum time to reset after power-on
Watchdog Timer Period tWD 0.1 1.6 2.5 s Typical watchdog timer period
Real-Time Clock Accuracy RTC - ±20 + ppm Typical accuracy over temperature range

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range (4.5V to 5.5V).
    • Connect the VCC pin to a stable 5V power source.
    • Ground the GND pin to the system ground.
  2. Standby Mode:

    • To minimize power consumption, use the standby mode by setting the appropriate control bits in the configuration registers.
    • In standby mode, the device consumes approximately 1.0 μA.
  3. Active Mode:

    • For active operation, ensure the device is powered and the necessary control signals are applied.
    • The maximum active current is 50 mA.
  4. Temperature Considerations:

    • The device operates reliably over the temperature range from -40°C to 85°C.
    • For optimal performance, avoid operating in extreme temperatures.
  5. Input/Output Levels:

    • Ensure that input signals meet the specified VIH and VIL levels.
    • Output signals will be within the specified VOH and VOL levels when driving the specified load currents.
  6. Propagation Delay:

    • Account for the typical propagation delay of 35 ns when designing timing-critical applications.
  7. Power-On Reset:

    • The device will reset automatically after a power-on delay of up to 400 ms.
    • Ensure that the system waits for this period before initiating communication with the device.
  8. Watchdog Timer:

    • The watchdog timer can be configured to generate a reset if the system does not service it within the specified period (0.1 to 2.5 seconds).
  9. Real-Time Clock:

    • The real-time clock provides accurate timekeeping with a typical accuracy of ±20 ppm over the operating temperature range.
    • Calibrate the clock as needed to maintain precise timekeeping.
  10. Configuration Registers:

    • Use the configuration registers to set up the device according to your application requirements.
    • Refer to the datasheet for detailed register descriptions and programming instructions.
  11. Communication Protocol:

    • The device supports standard communication protocols (e.g., I2C, SPI). Ensure the communication protocol is correctly configured and implemented.
  12. Handling and Storage:

    • Handle the device with care to avoid damage from electrostatic discharge (ESD).
    • Store the device in a dry, cool environment to prevent moisture-related issues.
(For reference only)

View more about DS1685EN-5+ on main site