L9779WD-SPI-TR Parameter Table

Parameter Symbol Min Typ Max Unit Condition
Input Voltage VIN 4.5 - 18 V
Output Voltage (Fixed) VOUT 3.3 - 3.3 V
Output Current IOUT - 3 5 A
Efficiency η - 95 - % @ 3.3V, 1A
Switching Frequency fSW - 2.1 - MHz
Quiescent Current IQ - 60 - μA No load, VIN = 12V
Load Regulation ΔVOUT/ΔI - 0.5 - %/A 0 to 5A
Line Regulation ΔVOUT/ΔVIN - 0.05 - %/V 4.5 to 18V
Output Ripple Vripple - 20 - mVpp @ 1A
Operating Temperature Range Toper -40 - 125 °C
Storage Temperature Range Tstg -65 - 150 °C
Package Type - SOIC-8 -

Instructions for Using L9779WD-SPI-TR

  1. Power Supply Connection:

    • Connect the input voltage (VIN) to the power supply.
    • Ensure the input voltage is within the specified range (4.5V to 18V).
  2. Output Configuration:

    • The output voltage (VOUT) is fixed at 3.3V.
    • Connect the load to the output pins.
  3. Ground Connection:

    • Ensure a solid ground connection (GND) to both the input and output circuits to maintain stability and reduce noise.
  4. Capacitor Selection:

    • Use a 10μF ceramic capacitor on the input side to filter out noise and provide a stable input voltage.
    • Use a 10μF ceramic capacitor on the output side to stabilize the output voltage and reduce ripple.
  5. Thermal Management:

    • Ensure adequate heat dissipation by using a heatsink or thermal pad if operating at high currents.
    • Monitor the temperature to ensure it stays within the operating range (-40°C to 125°C).
  6. SPI Communication:

    • The L9779WD-SPI-TR supports SPI communication for monitoring and control.
    • Connect the SPI lines (MISO, MOSI, SCK, CS) to your microcontroller or control circuit.
    • Refer to the datasheet for specific SPI commands and protocols.
  7. Protection Features:

    • The device includes overcurrent protection (OCP), overvoltage protection (OVP), and thermal shutdown to protect against faults.
    • Ensure these features are enabled and configured correctly for reliable operation.
  8. Storage and Handling:

    • Store the device in a dry, cool place away from direct sunlight.
    • Handle with care to avoid static discharge and physical damage.