Details
BUY IHW20N135R5,H20PR5 https://www.utsource.net/itm/p/12613903.html
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Drain-Source On-State Resistance at 25°C | RDS(on) | - | 135 | - | mΩ | VGS = 10V, ID = 20A |
Drain-Source On-State Resistance at 125°C | RDS(on) | - | 200 | - | mΩ | VGS = 10V, ID = 20A |
Continuous Drain Current | ID | - | - | 20 | A | TC = 25°C |
Pulse Drain Current (tp = 10ms) | ID(p) | - | - | 40 | A | TC = 25°C |
Gate-Source Voltage | VGS | -10 | - | 10 | V | - |
Drain-Source Breakdown Voltage | VDS(BR) | - | - | 650 | V | ID = 250μA |
Gate-Threshold Voltage | VGS(th) | 2.0 | 4.0 | 6.0 | V | ID = 250μA, TA = 25°C |
Total Power Dissipation | PTOT | - | - | 160 | W | TC = 25°C |
Junction Temperature | TJ | -55 | - | 175 | °C | - |
Storage Temperature Range | TSTG | -55 | - | 150 | °C | - |
Instructions:
Mounting:
- Ensure proper heat sinking to maintain junction temperature within specified limits.
- Use recommended PCB layout for optimal thermal performance.
Biasing:
- Apply gate-source voltage (VGS) within the specified range to avoid damage.
- For reliable operation, ensure VGS is at least 10V to fully turn on the device.
Current Handling:
- Do not exceed the continuous drain current (ID) or pulse drain current (ID(p)) ratings.
- For pulse operation, ensure the pulse width does not exceed 10ms to avoid thermal stress.
Voltage Ratings:
- Ensure the drain-source voltage (VDS) does not exceed the breakdown voltage (VDS(BR)).
- Keep the gate-source voltage (VGS) within the specified limits to prevent gate damage.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it stays within the operating range.
- Use appropriate cooling methods such as heatsinks or forced air cooling to manage heat dissipation.
Storage:
- Store the device in a dry environment with temperatures between -55°C and 150°C to prevent damage.
Handling:
- Handle the device with care to avoid mechanical damage.
- Use ESD protection to prevent static damage during handling and installation.
Testing:
- Perform initial testing under controlled conditions to verify proper operation.
- Regularly inspect the device for signs of wear or damage.
View more about IHW20N135R5,H20PR5 on main site