IHW20N135R5,H20PR5

IHW20N135R5,H20PR5


Specifications
SKU
12613903
Details

BUY IHW20N135R5,H20PR5 https://www.utsource.net/itm/p/12613903.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source On-State Resistance at 25°C RDS(on) - 135 - VGS = 10V, ID = 20A
Drain-Source On-State Resistance at 125°C RDS(on) - 200 - VGS = 10V, ID = 20A
Continuous Drain Current ID - - 20 A TC = 25°C
Pulse Drain Current (tp = 10ms) ID(p) - - 40 A TC = 25°C
Gate-Source Voltage VGS -10 - 10 V -
Drain-Source Breakdown Voltage VDS(BR) - - 650 V ID = 250μA
Gate-Threshold Voltage VGS(th) 2.0 4.0 6.0 V ID = 250μA, TA = 25°C
Total Power Dissipation PTOT - - 160 W TC = 25°C
Junction Temperature TJ -55 - 175 °C -
Storage Temperature Range TSTG -55 - 150 °C -

Instructions:

  1. Mounting:

    • Ensure proper heat sinking to maintain junction temperature within specified limits.
    • Use recommended PCB layout for optimal thermal performance.
  2. Biasing:

    • Apply gate-source voltage (VGS) within the specified range to avoid damage.
    • For reliable operation, ensure VGS is at least 10V to fully turn on the device.
  3. Current Handling:

    • Do not exceed the continuous drain current (ID) or pulse drain current (ID(p)) ratings.
    • For pulse operation, ensure the pulse width does not exceed 10ms to avoid thermal stress.
  4. Voltage Ratings:

    • Ensure the drain-source voltage (VDS) does not exceed the breakdown voltage (VDS(BR)).
    • Keep the gate-source voltage (VGS) within the specified limits to prevent gate damage.
  5. Thermal Management:

    • Monitor the junction temperature (TJ) to ensure it stays within the operating range.
    • Use appropriate cooling methods such as heatsinks or forced air cooling to manage heat dissipation.
  6. Storage:

    • Store the device in a dry environment with temperatures between -55°C and 150°C to prevent damage.
  7. Handling:

    • Handle the device with care to avoid mechanical damage.
    • Use ESD protection to prevent static damage during handling and installation.
  8. Testing:

    • Perform initial testing under controlled conditions to verify proper operation.
    • Regularly inspect the device for signs of wear or damage.
(For reference only)