SEM7150

SEM7150


Specifications
SKU
12614361
Details

BUY SEM7150 https://www.utsource.net/itm/p/12614361.html

Parameter Description Value
Part Number Full part number SEM7150
Type Device type MOSFET
Technology Technology used Silicon
Polarity Polarity of the device N-Channel
VDS (Max) Maximum Drain-Source Voltage 700 V
VGS (Max) Maximum Gate-Source Voltage 卤20 V
ID (Max) Maximum Drain Current at 25掳C 50 A
RDS(on) (Max) On-State Resistance at 25掳C 0.035 惟
Power Dissipation Maximum Power Dissipation 400 W
Operating Temp. Operating Temperature Range -55掳C to +175掳C
Package Package type TO-247
Lead Finish Lead finish Matte Tin
Mounting Type Mounting method Through-hole

Instructions for Use

  1. Handling and Storage:

    • Handle the SEM7150 with care to avoid damage to the leads and body.
    • Store in a dry, cool place to prevent moisture damage.
  2. Soldering:

    • Use a temperature-controlled soldering iron set to a maximum of 350掳C.
    • Ensure the soldering process is completed within 10 seconds to avoid thermal damage.
    • Allow the device to cool naturally after soldering.
  3. Circuit Design:

    • Ensure the drain-source voltage (VDS) does not exceed 700 V.
    • Keep the gate-source voltage (VGS) within 卤20 V to prevent gate oxide breakdown.
    • Do not exceed the maximum drain current (ID) of 50 A at 25掳C.
    • Consider the on-state resistance (RDS(on)) of 0.035 惟 when designing the circuit to minimize power loss.
  4. Thermal Management:

    • Use appropriate heat sinks to manage the power dissipation, especially when operating near the maximum power dissipation of 400 W.
    • Ensure adequate ventilation or forced air cooling if operating in high-temperature environments.
  5. Electrostatic Discharge (ESD) Protection:

    • Handle the device with ESD-protected tools and work surfaces.
    • Ground yourself before touching the device to prevent static discharge.
  6. Testing:

    • Use a multimeter to verify the continuity and resistance values before and after installation.
    • Perform functional tests under controlled conditions to ensure the device is operating correctly.
  7. Safety:

    • Always follow safety guidelines when working with high voltages and currents.
    • Disconnect power sources before making any changes to the circuit.
  8. Disposal:

    • Dispose of the device according to local regulations for electronic waste.
(For reference only)

View more about SEM7150 on main site