Details
BUY TH31AC06 https://www.utsource.net/itm/p/12614376.html
Below is the parameter table and instructions for the TH31AC06 triac:
TH31AC06 Parameter Table
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Repetitive Peak Off-State Voltage | VDRM | 400 | - | 600 | V | IT(AV) = 0.5A |
| Non-Repetitive Peak Off-State Voltage | VD(RMS) | 600 | - | 800 | V | ITSM = 12A |
| RMS On-State Current | IT(RMS) | - | 6 | - | A | VT = 0.9V |
| Latching Current | IL | 15 | - | 45 | mA | VT = 0.9V |
| Holding Current | IH | 5 | - | 15 | mA | VT = 0.9V |
| Gate Trigger Current (Random) | IGT(R) | 10 | - | 30 | mA | VT = 0.9V |
| Gate Trigger Current (Zero Cross) | IGT(Z) | 5 | - | 15 | mA | VT = 0.9V |
| Gate Trigger Voltage (Random) | VGT(R) | 0.5 | - | 1.5 | V | IGT = 30mA |
| Gate Trigger Voltage (Zero Cross) | VGT(Z) | 0.5 | - | 1.5 | V | IGT = 15mA |
| Thermal Resistance, Junction to Case | R胃JC | - | 2.0 | - | 掳C/W | - |
| Maximum Junction Temperature | TJ(max) | - | - | 125 | 掳C | - |
| Storage Temperature Range | Tstg | -40 | - | 125 | 掳C | - |
Instructions for TH31AC06
Handling and Storage:
- Store the device in a dry, cool place.
- Handle the device with care to avoid mechanical damage.
- Use appropriate ESD protection when handling the device.
Mounting:
- Ensure proper heat sinking if operating at high currents or temperatures.
- Use a thermal compound between the device and the heatsink for better thermal conductivity.
- Secure the device firmly to the heatsink to prevent mechanical stress.
Electrical Connections:
- Connect the main terminals (MT1 and MT2) to the load and power supply.
- Connect the gate terminal (G) to the control circuit.
- Ensure all connections are secure and free from oxidation.
Triggering:
- Apply a gate current (IGT) greater than the latching current (IL) to turn on the triac.
- For random phase triggering, use a gate current greater than IGT(R).
- For zero-cross triggering, use a gate current greater than IGT(Z).
Protection:
- Use a snubber circuit (RC network) across the main terminals to protect against voltage transients.
- Ensure the load current does not exceed the maximum RMS on-state current (IT(RMS)).
- Monitor the junction temperature to ensure it does not exceed TJ(max).
Testing:
- Test the device under controlled conditions to verify its operation.
- Use a multimeter to check continuity and resistance values.
- Perform functional tests with a known load to ensure proper triggering and switching.
Disposal:
- Dispose of the device according to local environmental regulations.
- Do not incinerate the device as it may release harmful substances.
By following these parameters and instructions, you can ensure reliable and safe operation of the TH31AC06 triac.
(For reference only)View more about TH31AC06 on main site