Details
BUY IXTP24N65X2 https://www.utsource.net/itm/p/12614872.html
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
|---|---|---|---|---|---|---|
| Maximum Drain-Source Voltage | VDS(max) | - | 650 | - | V | - |
| Maximum Gate-Source Voltage | VGS(max) | -20 | 0 | 20 | V | - |
| Continuous Drain Current (TC = 25掳C) | ID(25掳C) | - | 24 | - | A | - |
| Continuous Drain Current (TC = 100掳C) | ID(100掳C) | - | 18 | - | A | - |
| Pulse Drain Current (TC = 25掳C, 10 渭s) | IDpeak | - | 120 | - | A | - |
| Total Power Dissipation (TC = 25掳C) | PTOT(25掳C) | - | 300 | - | W | - |
| Total Power Dissipation (TC = 100掳C) | PTOT(100掳C) | - | 150 | - | W | - |
| Junction Temperature | TJ | - | - | 175 | 掳C | - |
| Storage Temperature Range | TSTG | -55 | - | 150 | 掳C | - |
| Thermal Resistance, Junction to Case | R胃JC | - | 0.4 | - | 掳C/W | - |
| Thermal Resistance, Junction to Ambient | R胃JA | - | 40 | - | 掳C/W | - |
Instructions for Use:
Handling and Storage:
- Store the device in a dry, cool place away from direct sunlight.
- Handle with care to avoid damage to the leads and the body of the device.
Mounting:
- Ensure proper heat sinking to manage thermal resistance and maintain junction temperature within safe limits.
- Use appropriate mounting hardware and thermal paste to enhance thermal conductivity.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Apply gate-source voltage (VGS) within the specified range to control the device.
- Ensure that the maximum drain-source voltage (VDS(max)) is not exceeded.
Operational Considerations:
- Monitor the continuous drain current (ID) and pulse drain current (IDpeak) to avoid exceeding the rated values.
- Keep the total power dissipation (PTOT) within the specified limits to prevent overheating.
- Regularly check the junction temperature (TJ) to ensure it does not exceed 175掳C.
Testing:
- Perform initial testing at room temperature (25掳C) to verify performance.
- Gradually increase the load and monitor the device parameters to ensure stable operation under all conditions.
Safety:
- Always use appropriate safety measures when handling high voltages and currents.
- Follow all relevant electrical and mechanical standards and regulations.
View more about IXTP24N65X2 on main site