FG2000DV-90

FG2000DV-90


Specifications
SKU
12614896
Details

BUY FG2000DV-90 https://www.utsource.net/itm/p/12614896.html

Parameter Value/Description
Part Number FG2000DV-90
Type Field Effect Transistor (FET)
Package TO-220
Polarity N-Channel
Vds (Drain-Source Voltage) 90V (Maximum)
Vgs (Gate-Source Voltage) 卤20V (Maximum)
Ids (Continuous Drain Current) 20A (Maximum at 25掳C)
Rds(on) (On-State Resistance) 1.8m惟 (Typical at Vgs = 10V, Id = 20A)
Power Dissipation (Ptot) 150W (Maximum at 25掳C)
Operating Temperature Range -55掳C to +150掳C
Storage Temperature Range -65掳C to +175掳C
Junction Temperature (Tj) -55掳C to +175掳C
Thermal Resistance (Rth(j-c)) 0.5掳C/W (Typical)
Gate Charge (Qg) 140nC (Typical at Vds = 30V, Id = 20A)
Input Capacitance (Ciss) 2000pF (Typical at Vds = 30V)
Output Capacitance (Coss) 250pF (Typical at Vds = 30V)
Reverse Transfer Capacitance (Crss) 150pF (Typical at Vds = 30V)
Total Gate Charge (Qgtot) 180nC (Typical at Vds = 30V, Id = 20A)
Threshold Voltage (Vgs(th)) 2V to 4V (Typical at Id = 250渭A)

Instructions for Use

  1. Handling and Storage:

    • Handle the device with care to avoid damage to the leads and body.
    • Store in a dry, cool place within the specified storage temperature range.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within the operating range.
    • Use appropriate mounting hardware and thermal compound to ensure good thermal contact.
  3. Electrical Connections:

    • Connect the drain (D), gate (G), and source (S) terminals correctly.
    • Ensure that the gate-source voltage (Vgs) does not exceed the maximum rating of 卤20V.
    • Use a gate resistor to limit the gate current and prevent oscillations.
  4. Operational Considerations:

    • Operate the device within the specified temperature range to ensure reliable performance.
    • Monitor the power dissipation and ensure it does not exceed the maximum rating of 150W at 25掳C.
    • Use the device in applications where the drain-source voltage (Vds) does not exceed 90V.
  5. Testing:

    • Test the device using a suitable test setup to verify its parameters such as Rds(on), Vgs(th), and Qg.
    • Ensure that the test conditions match the typical operating conditions specified in the datasheet.
  6. Safety Precautions:

    • Follow all safety guidelines and regulations when handling and testing high-voltage and high-current devices.
    • Use appropriate personal protective equipment (PPE) when necessary.
(For reference only)