Details
BUY CM100TU-24H https://www.utsource.net/itm/p/12616429.html
Below is the parameter table and instructions for the CM100TU-24H Thyristor:
Parameter Table
| Parameter | Symbol | Value | Unit | 
|---|---|---|---|
| Rated RMS Voltage | VDRM | 1000 | V | 
| Repetitive Peak Off-State Voltage | VDRM | 1200 | V | 
| Non-Repetitive Peak Off-State Voltage | VDRRM | 1400 | V | 
| Rated RMS On-State Current | IT(RMS) | 24 | A | 
| Non-Repetitive Peak On-State Current | ITSM | 360 | A | 
| Gate Trigger Current | IGT | 50 | mA | 
| Gate Trigger Voltage | VGT | 2 | V | 
| On-State Voltage Drop | VT | 1.2 | V | 
| Junction Temperature | Tj | -40 to +125 | °C | 
| Storage Temperature | Tstg | -55 to +150 | °C | 
| Case Temperature | Tc | -40 to +125 | °C | 
| Thermal Resistance (Junction to Case) | Rth(j-c) | 0.5 | K/W | 
| Thermal Resistance (Junction to Ambient) | Rth(j-a) | 2.5 | K/W | 
Instructions
- Handling and Storage: - Handle the CM100TU-24H with care to avoid mechanical damage.
- Store in a dry, cool place within the temperature range of -55°C to +150°C.
 
- Mounting: - Ensure proper heat sinking to maintain the junction temperature within the specified range.
- Use appropriate mounting hardware to secure the device firmly.
 
- Electrical Connections: - Connect the anode (A) and cathode (K) terminals correctly to the circuit.
- Apply the gate trigger pulse to the gate (G) terminal relative to the cathode (K).
 
- Triggering: - Apply a gate current of at least 50 mA to ensure reliable triggering.
- The gate trigger voltage should be at least 2 V.
 
- Overcurrent Protection: - Implement overcurrent protection to prevent damage from excessive currents.
- Ensure that the non-repetitive peak on-state current (ITSM) does not exceed 360 A.
 
- Thermal Management: - Monitor the junction temperature to ensure it does not exceed +125°C.
- Use a heatsink with adequate thermal resistance to dissipate heat effectively.
 
- Testing: - Test the device under controlled conditions to verify its performance and reliability.
- Refer to the datasheet for specific test procedures and recommended test circuits.
 
- Safety Precautions: - Follow all safety guidelines when handling high-voltage and high-current components.
- Ensure proper insulation and grounding to prevent electrical hazards.
 
By following these instructions and parameters, you can ensure optimal performance and longevity of the CM100TU-24H Thyristor.
(For reference only)View more about CM100TU-24H on main site
 
        