Details
BUY BZT03C47-TAP https://www.utsource.net/itm/p/12616737.html
Parameter | Symbol | Min | Typical | Max | Unit |
---|---|---|---|---|---|
Forward Voltage | Vf | - | 0.65 | 0.8 | V |
Reverse Breakdown Voltage | Vbr | 47 | - | 51 | V |
Maximum Repetitive Peak Reverse Voltage | Vrsm | 50 | - | - | V |
Average Rectified Output Current (at T = 25°C) | Ioav | - | 1.0 | - | A |
Surge Current (Non-repetitive) | Ism | - | 20 | - | A |
Operating Junction Temperature | Tj | -55 | - | 150 | °C |
Storage Temperature | Ts | -55 | - | 150 | °C |
Thermal Resistance (Junction to Ambient) | Rθja | - | 60 | - | K/W |
Instructions for Use:
Mounting:
- Ensure the device is mounted on a suitable heatsink if operating at high currents to maintain junction temperature within safe limits.
- Follow recommended soldering profiles to avoid thermal shock.
Electrical Connections:
- Connect the anode and cathode terminals correctly to avoid reverse polarity damage.
- Use appropriate wire gauges to handle the current ratings.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 150°C.
- Use thermal paste or thermal pads to improve heat transfer between the device and the heatsink.
Surge Handling:
- The device can handle surge currents up to 20A non-repetitively. Ensure that any transient conditions are within these limits.
Reverse Voltage:
- Do not exceed the maximum reverse voltage of 51V to prevent breakdown and potential damage.
Storage:
- Store the device in a dry, cool environment to prevent moisture damage.
- Handle with care to avoid mechanical stress on the leads.
Testing:
- Use a multimeter or diode tester to check the forward and reverse characteristics before installation.
- Perform in-circuit testing under controlled conditions to ensure proper operation.
View more about BZT03C47-TAP on main site