LTZ1000ACH

LTZ1000ACH

Category: IC Chips

Specifications
Details

BUY LTZ1000ACH https://www.utsource.net/itm/p/12623925.html

Parameter Symbol Min Typ Max Unit Description
Output Voltage VOUT 6.99 7.00 7.01 V Voltage output stability
Initial Accuracy -2 +2 mV Maximum deviation from nominal value at 25°C
Temperature Coefficient TCVOS -0.3 +0.3 ppm/°C Change in output voltage per degree Celsius
Long Term Stability LTS 2 μV/√kHr Voltage drift over time
Line Regulation LREG 0.2 μV/V Change in output voltage due to input voltage change
Load Regulation LDREG 0.8 μV/mA Change in output voltage due to load current change
Dropout Voltage VDROPOUT 1.5 V Minimum difference between input and output voltage for regulation
Supply Current ISUPPLY 9 mA Current consumed by the device
Operating Temperature TOPR -40 +85 °C Temperature range for operation
Storage Temperature TSTG -65 +150 °C Temperature range for storage

Instructions for Use

  1. Power Supply Requirements:

    • Ensure the input voltage is at least 1.5V higher than the desired output voltage to maintain regulation.
  2. Output Capacitor:

    • Connect a capacitor of at least 0.1μF directly across the output terminals for stability.
  3. Ground Connection:

    • Make sure the ground connections are solid and have low impedance to avoid noise and instability issues.
  4. Thermal Considerations:

    • The device can operate within an ambient temperature range of -40°C to +85°C. For applications outside this range, ensure adequate thermal management.
  5. Load Regulation:

    • To minimize load regulation errors, keep the load current within specified limits and use appropriate decoupling capacitors if necessary.
  6. Initial Setup:

    • Verify the initial accuracy and adjust external components if required for precise voltage settings.
  7. Long-Term Stability:

    • Regularly monitor the output voltage over time to ensure it remains within acceptable limits as specified by the long-term stability parameter.
  8. Handling Precautions:

    • Handle with care to avoid damage from electrostatic discharge (ESD). Use proper ESD protection practices during installation and handling.
(For reference only)

View more about LTZ1000ACH on main site