7MBR30LC060

7MBR30LC060


Specifications
SKU
386135
Details

BUY 7MBR30LC060 https://www.utsource.net/itm/p/386135.html
PIM/Built-in converter with thyristor and brake S series 600V / 30A / PIM
Parameter Symbol Min Typ Max Unit Description
Blocking Voltage V(BR) 600 V Maximum repetitive peak reverse voltage
Average Rectified Current I(F(AV) 30 A RMS current in a resistive load
Peak Recurrent Surge Current I(FSM) 200 A Non-repetitive peak surge current
Junction Temperature T(J) -40 150 掳C Operating junction temperature
Storage Temperature T(STG) -40 150 掳C Storage temperature range
Forward Voltage Drop V(F) 1.0 1.2 V @ IF Forward voltage at specified forward current
Reverse Recovery Time t(RR) 75 ns Time taken for diode to recover from on state to off state
Thermal Resistance, Junction to Ambient R(胃JA) 40 掳C/W Thermal resistance from junction to ambient

Instructions:

  1. Mounting: Ensure the device is mounted with adequate heat sinking if operating near maximum current or in high ambient temperatures.
  2. Voltage Handling: Do not exceed the maximum blocking voltage (V(BR)) of 600V to prevent breakdown and potential damage.
  3. Current Ratings: Operate within the average rectified current (I(F(AV))) limits to avoid overheating. For transient conditions, ensure peak recurrent surge current (I(FSM)) does not exceed 200A.
  4. Temperature Management: Keep the junction temperature (T(J)) between -40掳C and 150掳C. Exceeding these limits can lead to permanent damage.
  5. Storage Conditions: Store the device in environments where the temperature stays between -40掳C and 150掳C (T(STG)).
  6. Forward Voltage Monitoring: Monitor the forward voltage drop (V(F)) which should typically be between 1.0V and 1.2V under normal operating conditions.
  7. Reverse Recovery Consideration: Be aware of the reverse recovery time (t(RR)) of 75ns, crucial for high-frequency applications to avoid excessive power dissipation during switching.
  8. Thermal Design: Incorporate thermal management strategies considering the thermal resistance (R(胃JA)) to maintain optimal operating temperatures.
(For reference only)

View more about 7MBR30LC060 on main site