Details
BUY DDB6U100N14R https://www.utsource.net/itm/p/415282.html
Diode Bridges; Package: AG-ECONO2-1; VDRM/ VRRM V: 1,600.0 V; IFSM max: 550.0 A; Configuration: 3 phase bridge rectifier uncontrolled; Housing: EconoBRIDGE;
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | VIN | 100 | V | Maximum rated input voltage | ||
Output Voltage | VOUT | 14 | V | Rated output voltage | ||
Continuous Current | IOUT | 6 | A | Continuous output current | ||
Peak Current | IPEAK | 10 | A | Peak output current | ||
Efficiency | η | 92 | % | Typical efficiency | ||
Operating Temperature | TOPR | -40 | 85 | °C | Operating temperature range | |
Storage Temperature | TSTG | -55 | 125 | °C | Storage temperature range | |
Junction Temperature | TJ | 150 | °C | Maximum junction temperature | ||
Power Dissipation | PD | 1.5 | W | Power dissipation at nominal conditions | ||
Ripple Current | Iripple | 3 | A | RMS ripple current | ||
Isolation Voltage | VISOL | 1500 | Vrms | Input to output isolation voltage |
Instructions for DDB6U100N14R:
Power Supply Connection:
- Connect the input voltage (VIN) within the specified range.
- Ensure the output voltage (VOUT) is set to the required value, typically 14V.
Current Handling:
- Do not exceed the continuous current (IOUT) of 6A or peak current (IPEAK) of 10A to avoid damage.
Thermal Management:
- Operate within the temperature range (-40°C to 85°C) and ensure proper heat dissipation to prevent exceeding the maximum junction temperature (TJ).
Efficiency Monitoring:
- Monitor the efficiency (η) to ensure optimal performance, typically around 92%.
Storage Conditions:
- Store in an environment where temperatures do not exceed the storage temperature range (-55°C to 125°C).
Safety Considerations:
- Ensure isolation voltage (VISOL) requirements are met to maintain safety standards.
Installation:
- Securely mount the device to a heatsink if necessary to manage power dissipation (PD).
Testing:
- Verify ripple current (Iripple) does not exceed 3A to ensure stable operation.
Note: Always refer to the manufacturer's datasheet for the most accurate and detailed specifications and instructions.
(For reference only)View more about DDB6U100N14R on main site