Details
BUY MAX7400ESA https://www.utsource.net/itm/p/513475.html
8 t h-Order, Lowpass, Ellip t ic, Swi t ched-Capaci t or Fil t ers
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage | VIN | Operating | 4.5 | - | 5.5 | V |
| Output Voltage | VOUT | Guaranteed | 1.2 | - | 3.3 | V |
| Output Current | IOUT | Continuous | - | 500 | - | mA |
| Quiescent Current | IQ | VIN = 5V, No Load | - | 5 | - | 渭A |
| Dropout Voltage | VDROPOUT | IOUT = 500mA | - | 300 | - | mV |
| Power Dissipation | PD | Maximum | - | - | 1250 | mW |
| Operating Temperature | TOPR | Junction | -40 | - | 85 | 掳C |
| Storage Temperature | TSTG | -65 | - | 150 | 掳C |
Instructions for MAX7400ESA
Power Supply Connection:
- Connect the input voltage (VIN) to a stable power supply within the operating range of 4.5V to 5.5V.
- Ensure that the output capacitor is placed close to the device for stability.
Output Configuration:
- Set the desired output voltage using the external resistors or select from the pre-set options available in the MAX7400ESA series.
- Verify that the output voltage is within the guaranteed range of 1.2V to 3.3V.
Load Handling:
- The device can provide up to 500mA of continuous output current. Ensure that the load does not exceed this limit to avoid overheating or damage.
Thermal Management:
- Keep the operating temperature between -40掳C and 85掳C. For applications with high ambient temperatures, consider additional cooling methods such as heatsinks.
- Avoid exposing the device to storage temperatures outside the -65掳C to 150掳C range.
Efficiency Considerations:
- Monitor the power dissipation, which should not exceed 1250mW to maintain reliable operation.
- Optimize the circuit design to minimize quiescent current and maximize efficiency.
Stability and Noise:
- Use appropriate bypass capacitors at the input and output to reduce noise and ensure stable operation.
- Refer to the datasheet for recommended capacitor types and values.
View more about MAX7400ESA on main site