Details
BUY ADC0801LCN https://www.utsource.net/itm/p/523282.html
8-Bit uP Compatible A/D Converters
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating condition | 4.75 | 5 | 5.25 | V |
| Reference Voltage | Vref | 0 | Vcc | V | ||
| Analog Input Voltage | Vin | 0 | Vref | V | ||
| Conversion Time | tconv | fCLK = 5MHz | 1.2 | 渭s | ||
| Resolution | 8 | bits | ||||
| Differential Nonlinearity | DNL | -1 | +1 | LSB | ||
| Integral Nonlinearity | INL | -1 | +1 | LSB | ||
| Power Consumption | IDD | fCLK = 5MHz, TA=25掳C | 10 | 30 | mA | |
| Output Impedance | Zout | 50 | 惟 |
Instructions for ADC0801LCN
Power Supply Connection:
- Connect the supply voltage (Vcc) between 4.75V and 5.25V to ensure stable operation.
- Ground all necessary pins to maintain reference levels.
Reference Voltage Setup:
- Set the reference voltage (Vref) as required. It can range from 0V to Vcc.
Clock Configuration:
- Provide a clock signal to the CLK pin. The conversion time is dependent on the frequency of this clock. For optimal performance, use a clock frequency of 5MHz.
Analog Input:
- Apply the analog input voltage within the range of 0V to Vref. Ensure that the input voltage does not exceed the reference voltage to prevent damage.
Digital Output Reading:
- After initiating a conversion, wait for the conversion time (tconv) before reading the digital output. This ensures accurate data acquisition.
Power Consumption Consideration:
- Be aware of the power consumption, which can be up to 30mA at 5MHz and 25掳C ambient temperature. Design your power supply accordingly.
Output Handling:
- The output impedance is around 50惟. Ensure that the load connected to the output can handle this impedance without significant signal degradation.
Operating Temperature:
- The device is designed to operate reliably within a specified temperature range. Check the datasheet for specific temperature limits to avoid operational issues.
Handling Static Electricity:
- Handle the ADC0801LCN with care to avoid damage from static electricity. Use proper anti-static precautions during handling and installation.
View more about ADC0801LCN on main site