Details
BUY OP297GP https://www.utsource.net/itm/p/1100616.html
Dual Low Bias Current Precision Operational Amplifier
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Input Voltage Range | V_IN | -0.3 | 36 | V | ||
| Output Voltage Range | V_OUT | No load | -0.3 | 36 | V | |
| Supply Current | I_S | V_S = 卤15V, no load | 2.7 | mA | ||
| Input Offset Voltage | V_IO | V_CM = 0 to 10V | -20 | 0 | 20 | 渭V |
| Input Bias Current | I_B | V_CM = 0 to 10V | -1 | 0 | 1 | nA |
| Input Offset Current | I_IO | V_CM = 0 to 10V | -10 | 0 | 10 | pA |
| Large Signal Voltage Gain | A_V | V_CM = 0V, R_L = 10k惟 | 250 | V/mV | ||
| Slew Rate | SR | V_S = 卤15V, V_O = 卤10V | 0.3 | V/渭s | ||
| Common Mode Rejection Ratio | CMRR | f = 0.1Hz to 10Hz | 140 | dB | ||
| Power Supply Rejection Ratio | PSRR | f = 0.1Hz to 10Hz | 140 | dB |
Instructions for Use:
Power Supply:
- Ensure the supply voltage is within the specified range (-0.3V to 36V). The OP297GP can operate with a single or dual power supply.
Input Signals:
- Keep input signals within the common-mode voltage range to avoid distortion and ensure accurate amplification.
Biasing:
- The low input bias current means that this op-amp is suitable for high impedance sources. Care should be taken to properly bias the inputs when interfacing with such sources.
Output Load:
- For optimal performance, connect a load resistor (e.g., 10k惟) to the output to match the typical conditions under which the large signal voltage gain is specified.
Stability:
- The OP297GP is internally compensated for unity-gain stability. External compensation is generally not required unless specific frequency response adjustments are needed.
Temperature Considerations:
- Although not detailed in the table, consider the temperature range of operation as it can affect parameters like input offset voltage and bias currents.
Handling Static Electricity:
- Handle the device with care to avoid damage from static electricity, especially during soldering or handling.
Testing and Troubleshooting:
- When testing, use the specified conditions for accurate measurement of parameters. Troubleshoot by checking connections, power supply integrity, and signal levels at each stage.
View more about OP297GP on main site