AT24C16A-10PU-2.7

AT24C16A-10PU-2.7

Category: IC Chips

Specifications
SKU
1112836
Details

BUY AT24C16A-10PU-2.7 https://www.utsource.net/itm/p/1112836.html
CAP 150UF 10V 20% TANT SMD-6032-28 TR-7
Parameter Description Value Unit
Storage Temperature Operating temperature range for storage -55 to +125 °C
Operating Temperature Operating temperature range -40 to +85 °C
Supply Voltage Range Voltage supply range 2.7 to 5.5 V
Capacity Memory capacity 16 Kbits
Organization Memory organization 2048 x 8 bits
Package Type Package type PDIP
Pin Count Number of pins 8
Write Cycle Time Time required for a write cycle 5 ms
Endurance Guaranteed number of write/erase cycles 1,000,000
Data Retention Guaranteed data retention period 100 years
Standby Current Current consumption in standby mode 1 μA
Operating Current Current consumption during operation 3 mA

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage is within the specified range (2.7V to 5.5V).
    • Avoid exceeding these limits to prevent damage to the device.
  2. Temperature Considerations:

    • Operate within the temperature range (-40°C to +85°C) to ensure reliable performance.
    • Store the device within the storage temperature range (-55°C to +125°C).
  3. Write Operations:

    • Allow at least 5ms for each write cycle to complete before initiating another write or read operation.
    • Do not exceed 1,000,000 write/erase cycles to maintain device integrity.
  4. Data Integrity:

    • Data can be retained for up to 100 years under proper operating conditions.
    • For optimal data retention, avoid exposing the device to extreme temperatures and voltages outside the specified ranges.
  5. Current Consumption:

    • In standby mode, the device consumes approximately 1μA.
    • During active operations, it consumes around 3mA.
  6. Installation:

    • Ensure correct orientation when installing into the PDIP socket.
    • Verify pin connections are secure and correctly aligned.
  7. Handling Precautions:

    • Handle with care to avoid static discharge which can damage the component.
    • Follow ESD (Electrostatic Discharge) precautions during handling and installation.