RS5C583

RS5C583


Specifications
SKU
1253166
Details

BUY RS5C583 https://www.utsource.net/itm/p/1253166.html
ULTRA-COMPACT REAL-TIME CLOCK IC
Parameter Description Conditions Min Typ Max Unit
Supply Voltage (VCC) Operating supply voltage range 1.8 5.5 V
Standby Current Current consumption in standby mode VCC = 3.0V 0.2 渭A
Operating Current Current consumption during operation VCC = 3.0V, fosc = 32.768kHz 0.9 渭A
Frequency Range Oscillator frequency range 32.768 32.768 kHz
Temperature Range Operating temperature range -40 85 掳C
Output Voltage High Logic high output voltage IOH = -1.0mA 4.5 V
Output Voltage Low Logic low output voltage IOL = 1.6mA 0.4 V

Instructions for RS5C583:

  1. Power Supply Connection:

    • Connect the VCC pin to a power supply within the specified voltage range (1.8V to 5.5V).
    • Ensure a stable and clean power supply to avoid noise affecting the device performance.
  2. Oscillator Configuration:

    • The RS5C583 uses an external 32.768 kHz crystal oscillator for timing.
    • Properly connect the crystal and load capacitors as per the manufacturer's guidelines to ensure accurate timekeeping.
  3. Standby Mode:

    • To enter standby mode, set the appropriate control signal or use the provided register settings.
    • This reduces current consumption significantly, useful for battery-operated devices.
  4. Operating Mode:

    • For normal operation, ensure the oscillator is running and the device is configured to perform its intended functions.
    • Monitor the operating current to ensure it stays within typical values for efficient power usage.
  5. Temperature Considerations:

    • Operate the device within the specified temperature range (-40掳C to 85掳C) to maintain reliable performance.
    • Extreme temperatures can affect the accuracy of the real-time clock function.
  6. Output Handling:

    • When interfacing with other circuits, ensure that the logic levels (high and low voltages) are compatible with the connected devices.
    • Use appropriate pull-up or pull-down resistors if necessary to stabilize the output signals.
  7. Programming and Setup:

    • Refer to the datasheet for specific programming instructions and register configurations.
    • Utilize initialization routines to set up the device according to your application requirements.
(For reference only)