BUY TLP641G https://www.utsource.net/itm/p/1403416.html
Thyrister Output Photocouplers and Photorelays; Features: Standard; Package: DIP6; Surface Mount Type: Y/N; Number of Pins: 6; Trigger LED Current I_FT, max mA: 7; On-state voltage V_TM @I_TM=100mA max V: 1.3; Peak off-state voltage V_DRM max V: 400; Isolation voltage BVs @1minute min V_rms: 5000
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 10 mA | 1.2 | 1.6 | V | |
Peak Forward Current | IFM | t = 1 ms, Repetition Rate = 100/s | 30 | mA | ||
Reverse Voltage | VR | 5 | V | |||
Output Current | ICM | tp = 1 ms | 0.5 | A | ||
Isolation Voltage | VIORM | 1 minute, 50/60 Hz | 5000 | Vrms | ||
Turn-ON Time | ton | IF = 10 mA, IL = 10 mA | 4 | 6 | μs | |
Turn-OFF Time | toff | IF = 10 mA, IL = 10 mA | 2 | 4 | μs |
Instructions for Use:
Mounting and Handling:
- Handle the TLP641G with care to avoid mechanical damage.
- Ensure proper heat dissipation if operating at high currents.
Electrical Connections:
- Connect the forward current (IF) source to the appropriate terminals.
- Ensure reverse voltage (VR) does not exceed the maximum rating.
Operating Conditions:
- Operate within specified temperature and humidity ranges to ensure reliable performance.
- Avoid exceeding peak forward current (IFM) and output current (ICM) ratings.
Safety Precautions:
- Respect isolation voltage (VIORM) limits to prevent electrical hazards.
- Implement adequate safety measures when working with high voltages.
Testing and Troubleshooting:
- Measure turn-on and turn-off times under typical conditions to verify correct operation.
- If issues arise, check all connections and ensure parameters are within specified limits.
For detailed specifications and additional information, refer to the official datasheet provided by Toshiba.
(For reference only)View more about TLP641G on main site