Details
BUY FS200R06KL4 https://www.utsource.net/itm/p/1570742.html
IGBT-inverter
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Breakdown Voltage | V(BR)DSS | 600 | V | Drain-Source Breakdown Voltage | ||
Continuous Drain Current | ID | 200 | A (Tc=25°C) | Continuous Drain Current at Tc = 25°C | ||
Power Dissipation | PD | 175 | W | Maximum Power Dissipation (TC = 25°C) | ||
Junction Temperature | TJ | -55 | 175 | °C | Operating Junction Temperature Range | |
Gate Charge | Qg | 93 | nC | Total Gate Charge at VGS = ±15V | ||
Input Capacitance | Ciss | 4800 | pF | Input Capacitance at VDS = 30V, VGS = 0V | ||
Output Capacitance | Coff | 120 | pF | Output Capacitance at VDS = 30V, IDS = 0A | ||
Reverse Transfer Capacitance | Crss | 1200 | pF | Reverse Transfer Capacitance at VDS = 30V |
Instructions for Use:
Handling and Storage:
- Store in a dry environment to prevent moisture damage.
- Handle with care to avoid static damage; use ESD-safe practices.
Mounting:
- Ensure proper thermal management by using heatsinks or heat spreaders if necessary.
- Follow recommended PCB layout guidelines for optimal performance and reliability.
Operation:
- Do not exceed the maximum ratings provided in the table.
- Ensure that the junction temperature remains within specified limits during operation.
- For best performance, operate within the recommended operating conditions.
Testing:
- Verify all connections are secure before applying power.
- Test under controlled conditions to ensure the device is functioning correctly.
Safety:
- Always follow safety protocols when working with high voltage and current levels.
- Use appropriate protective equipment and observe all warnings related to electrical safety.