Details
BUY FF450R12ME4 https://www.utsource.net/itm/p/1865197.html
EconoDUAL3 module with Trench/Fieldstop IGBT4 and Emitter Controlled HE diode and NTC
| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Rated Voltage | VDSS | 1200 | V | Maximum repetitive peak off-state voltage | ||
| Continuous Drain Current | ID | 450 | A (Tc=25掳C) | RMS output current | ||
| Total Losses | PTOT | W | Total power losses at specified conditions | |||
| Junction Temperature | Tj | -40 | 150 | 掳C | Operating junction temperature range | |
| Storage Temperature | Tstg | -40 | 100 | 掳C | Storage temperature range | |
| Thermal Resistance | Rth | 0.16 | K/W | Junction to case thermal resistance | ||
| Switching Frequency | fsw | 20 | kHz | Recommended switching frequency |
Instructions for FF450R12ME4
Installation:
- Ensure the device is mounted on a heatsink with adequate thermal conductivity to maintain junction temperature within operational limits.
- Use recommended mounting torque for screws to avoid damage.
Operating Conditions:
- Do not exceed the maximum rated voltage of 1200V to prevent breakdown.
- Keep continuous drain current within 450A at 25掳C case temperature to avoid overheating.
Thermal Management:
- Monitor junction temperature to ensure it does not exceed 150掳C.
- Adequate cooling mechanisms should be in place, especially if operating near the maximum current or in high ambient temperatures.
Switching Operations:
- Operate within the recommended switching frequency of up to 20kHz to minimize switching losses and ensure reliable performance.
Storage:
- Store the device in a dry environment within the temperature range of -40掳C to 100掳C to prevent damage.
Handling Precautions:
- Handle with care to avoid mechanical damage.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
View more about FF450R12ME4 on main site
