BTA06-600CW

BTA06-600CW


Specifications
SKU
4304423
Details

BUY BTA06-600CW https://www.utsource.net/itm/p/4304423.html
SNUBBERLESS?, LOGIC LEVEL & STANDARD
Parameter Symbol Min Typ Max Unit Conditions
Rated ON-state current IT(RMS) - 6 - A Tj = 40掳C
Peak ON-state current ITSM - 60 - A Tj = 40掳C, 1.5ms pulse, 2% duty cycle
Maximum OFF-state voltage VDRM - 600 - V
Maximum repetitive peak off-state voltage VRRM - 600 - V
Gate trigger current IG(T) 5 - 50 mA
Holding current IH 5 - 50 mA
Junction temperature Tj -55 - 125 掳C

Instructions for Use:

  1. Installation: Ensure the BTA06-600CW is mounted on a suitable heatsink to maintain operational temperatures within specified limits.
  2. Gate Triggering: Apply a gate current (IG(T)) of at least 5mA to ensure reliable turn-on. Do not exceed 50mA to avoid damage.
  3. Current Handling: Operate within the rated RMS current (IT(RMS)) of 6A and do not exceed the peak ON-state current (ITSM) of 60A for pulses lasting up to 1.5ms with a 2% duty cycle.
  4. Voltage Limits: Ensure the applied voltage does not exceed the maximum OFF-state voltage (VDRM) of 600V or the maximum repetitive peak off-state voltage (VRRM) of 600V.
  5. Temperature Management: Keep the junction temperature (Tj) between -55掳C and 125掳C to prevent thermal stress or failure.
  6. Holding Current: Ensure the holding current (IH) remains above 5mA to maintain the device in the ON state.

For detailed application notes and further information, refer to the manufacturer's datasheet.

(For reference only)

View more about BTA06-600CW on main site