Details
BUY LTC2901-1CGN#TRPBF https://www.utsource.net/itm/p/4790718.html
IC MONITOR SUPPLY QUAD 16-SSOP
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 2.7 | - | 5.5 | V |
Quiescent Current | IQ | VCC = 3V | - | 40 | - | μA |
Output Voltage Accuracy | ΔVOUT | VREF = 1.21V | - | ±1.0 | - | % |
Power-On Reset Threshold | VPOK | Rising | 2.23 | - | 2.68 | V |
Power-Good Hysteresis | VHYST | 20 | - | 60 | mV | |
Watchdog Timer Period | TWD | RWD = 1MΩ, VCC = 3V | 1.6 | - | 2.4 | s |
Manual Reset Input Voltage | VMR | Active Low | 0 | - | 0.8 | V |
Reset Output Voltage Level | VRO | Active Low | 0 | - | 0.4 | V |
Instructions for Use:
Power Supply Connection:
- Connect the supply voltage (VCC) to the appropriate pin. Ensure that the voltage is within the operating range of 2.7V to 5.5V.
Output Voltage Configuration:
- The LTC2901-1CGN#TRPBF provides a fixed output reference voltage of 1.21V with ±1.0% accuracy. No external components are required for this configuration.
Power-Good Monitoring:
- The device monitors the input voltage and asserts the power-good signal (PGOOD) when the input voltage exceeds the rising threshold (VPOK). The hysteresis ensures stable operation during power transitions.
Watchdog Timer:
- A watchdog timer can be enabled by connecting an external resistor (RWD) to set the timeout period. For RWD = 1MΩ at VCC = 3V, the typical timeout period is between 1.6s and 2.4s.
Manual Reset:
- The manual reset input (MR) can be pulled low to trigger a system reset. Ensure that the voltage on this pin does not exceed 0.8V when active.
Reset Output:
- The reset output (RESET) goes low when any reset condition is met (power-on reset, watchdog timeout, or manual reset).
PCB Layout Considerations:
- Place bypass capacitors close to the VCC and GND pins to ensure stability and reduce noise.
- Keep signal traces short and direct to minimize potential interference.
Operating Temperature Range:
- The device is specified to operate over the industrial temperature range from -40°C to +85°C.
For detailed application notes and further information, refer to the official datasheet provided by Analog Devices.
(For reference only)View more about LTC2901-1CGN#TRPBF on main site