BUY MAX3232CWE+T https://www.utsource.net/itm/p/4870836.html
IC TRANSCEIVER FULL 2/2 16SOIC
Parameter | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage (VCC) | Operating | 3.0 | 5.5 | V | |
Operating Temperature | Commercial | -40 | 85 | °C | |
Driver Output Voltage | VCC = 5V, RL = 5kΩ | 5.0 | 5.5 | V | |
Driver Output Voltage | VCC = 3.3V, RL = 5kΩ | 3.0 | 3.6 | V | |
Receiver Input Voltage | VIH | 2.0 | 5.5 | V | |
Receiver Input Voltage | VIL | -5.0 | 0.8 | V | |
Driver Output Current | High-Level Output Current | 10 | mA | ||
Driver Output Current | Low-Level Output Current | -10 | mA | ||
Propagation Delay Time | TPLH, TPHL, VCC = 5V | 35 | ns | ||
Propagation Delay Time | TPLH, TPHL, VCC = 3V | 50 | ns | ||
Skew | VCC = 5V | 5 | ns | ||
Power Dissipation | Per Channel | 1.7 | mW |
Instructions for Use:
- Power Supply: Ensure the supply voltage (VCC) is within the specified range of 3.0V to 5.5V.
- Temperature Range: Operate the device within the commercial temperature range of -40°C to +85°C.
- Driver Outputs: Connect the driver outputs to loads that comply with the output voltage and current specifications.
- Receiver Inputs: Ensure receiver inputs do not exceed the maximum input voltages specified.
- Timing Considerations: Account for propagation delays and skew in your system design, especially in high-speed applications.
- Power Management: Be mindful of power dissipation per channel to avoid overheating.
For detailed application notes and further instructions, refer to the official MAX3232CWE+T datasheet provided by Maxim Integrated.
(For reference only)View more about MAX3232CWE+T on main site