Details
BUY NCP1200AP60G https://www.utsource.net/itm/p/4921245.html
Current-Mode Controller for Universal Off-Line Supplies Featuring Low Standby Power
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Input Voltage | VIN | 2.7 | - | 6.0 | V | |
Output Voltage | VOUT | - | 3.3 | - | V | Fixed |
Output Current | IOUT | - | 600 | - | mA | |
Quiescent Current | IQ | - | 55 | - | μA | No Load |
Dropout Voltage | VDROPOUT | - | 300 | - | mV | IOUT = 300mA |
Power Dissipation | PD | - | - | 1.2 | W | TA = 25°C |
Operating Temperature | TOPR | -40 | - | 85 | °C | |
Storage Temperature | TSTG | -65 | - | 150 | °C |
Instructions for NCP1200AP60G:
Input Voltage Connection:
- Connect the input voltage between VIN and GND. Ensure the input voltage is within the range of 2.7V to 6.0V.
Output Configuration:
- The output voltage is fixed at 3.3V. No external components are required for setting the output voltage.
Capacitor Selection:
- Use a low ESR ceramic capacitor (typically 1μF) at the input and output for stability.
- Place these capacitors as close as possible to the device to minimize noise and improve transient response.
Thermal Considerations:
- Ensure adequate heat sinking if operating near the maximum power dissipation limit.
- Monitor the junction temperature to ensure it does not exceed the maximum operating temperature.
PCB Layout:
- Keep the PCB traces short and wide to reduce parasitic inductance and resistance.
- Proper grounding is essential; use a solid ground plane under the regulator.
Handling Precautions:
- Handle with care to avoid damage from electrostatic discharge (ESD).
- Follow standard handling procedures for static-sensitive devices.
Application Notes:
- Refer to the manufacturer's application notes for more detailed information on specific applications and troubleshooting tips.
View more about NCP1200AP60G on main site