Details
BUY UC2845BD1013TR https://www.utsource.net/itm/p/5343020.html
HIGH PERFORMANCE CURRENT MODE PWM CONTROLLER
Parameter | Symbol | Min | Typical | Max | Unit | Description |
---|---|---|---|---|---|---|
Input Voltage | V_IN | 7 | - | 40 | V | Operating input voltage range |
Switching Frequency | f_SW | 100 | - | 500 | kHz | Adjustable switching frequency |
Maximum Duty Cycle | D_MAX | - | 95 | - | % | Maximum duty cycle of the PWM output |
Start-Up Current | I_START | - | 20 | - | μA | Initial current required for startup |
Quiescent Current | I_Q | - | 3.5 | - | mA | Current consumption in quiescent state |
Error Amplifier Gain | A_EA | - | 60 | - | dB | Gain of the error amplifier |
Reference Voltage | V_REF | - | 2.5 | - | V | Internal reference voltage |
Compensation Pin Output | V_COMP | - | 2.5 | - | V | Output voltage at compensation pin |
Overcurrent Protection | I_OCP | - | 1.0 | - | A | Threshold for overcurrent protection |
Instructions for UC2845BD1013TR
Power Supply Connection:
- Connect the input voltage (V_IN) to the appropriate power supply within the specified range (7V to 40V).
Frequency Setting:
- Adjust the switching frequency using an external resistor connected to the RT/CT pin. The typical frequency range is from 100kHz to 500kHz.
Duty Cycle Control:
- The maximum duty cycle is set internally to 95%. Ensure that the design does not exceed this limit to avoid malfunction.
Startup and Operation:
- Ensure that the start-up current (I_START) requirements are met for proper initialization. The device typically requires about 20μA.
Error Amplifier Usage:
- Use the error amplifier for feedback control. It has a gain of approximately 60dB, aiding in precise regulation.
Reference Voltage:
- The internal reference voltage (V_REF) is set to 2.5V. This voltage can be used as a stable reference point for various circuit components.
Compensation Network:
- Design a compensation network around the COMP pin to stabilize the feedback loop, ensuring stability and performance.
Overcurrent Protection:
- Monitor the overcurrent protection threshold (I_OCP) which is set to 1.0A to safeguard against excessive currents.
Quiescent Current Management:
- Be mindful of the quiescent current (I_Q) of 3.5mA, as it affects overall efficiency, especially in low-power applications.
For detailed application notes and further specifications, refer to the manufacturer's datasheet or official documentation.
(For reference only)View more about UC2845BD1013TR on main site